Welcome to
Midwest-Group

Free Member
Midwest-Group
Midwest-Group
China
  • Products Catalog

    Liquid-Phase Photosynthesis & Respiration Measurement

    Quantity Order:
    Payment Method:
    Telegraphic Transfer (T/T)

    Specification :

    Features

    * Peltier oxygen electrode unit with integral thermoelectric temperature control.
    * Compact design with integral electronics and magnetic stirrer.
    * Computer controlled oxygen electrode system with direct on-screen display of traces.
    * Custom Windows® software for instrument control and data analysis.
    * System expansion to 8 channels via
    purchase of additional components.

    Overview

    he Oxytherm oxygen electrode system provides an affordable and convenient method of measuring oxygen uptake or evolution in liquid-phase samples in cellular respiration or photosynthesis research applications. It additionally provides precise temperature control of the reaction vessel and sample using an integral thermoelectric module and requires no supply of circulating water.

    Main Component

    Oxygen Electrode Control unit

    * PC operated Oxytherm oxygen electrode control unit suitable for liquid and gas-phase measurements in cellular respiration & photosynthesis research
    * Peltier electrode chamber with integral thermoelectric temperature control
    * Compact design with integral electronics & magnetic stirrer
    * System expansion to 8 channels via purchase of additional components
    * Real time chart recorder emulation of O2 signal & optional auxiliary input
    * Custom Windows® software for hardware control & data analysis

    Technical Specification

    OXYT1 Oxytherm Electrode Control Unit

    Measuring Range: 0 - 40% oxygen

    Min. O-2 Resolution :
    Typically 10 x 10-6 µ mols/ ml at 20 ° C

    Integral Magnetic Stirrer Software controlled between :
    150 - 900rpm in % steps
    Polarising Voltage: 700mV

    Gain/ Back Off Control : Software adjustable.

    Gain: up to x50 ( 10 bit resolution) .

    Back off: 12 bit resolution

    Integral Test Resistor Yes

    Signal Inputs Electrode disc connection: Auxiliary input

    Data Acquisition Rate :
    Software selectable between 0.2 - 10 readings per second

    Communications :
    Bi-directional RS232. USB using HAN/ USB adapter ( supplied)
    Dimensions :
    250 ( w) x 126 ( d) x 136mm ( h) .
    Weight: 1.27Kg

    Power Supply :
    95 - 260V universal input mains supply.

    Output 12V DC 2.5A

    Peltier Electrode Chamber Temp range: 3 - 40° C ( 25° C ambient) .Response time: