    Dialyzer reprocessing machine

    Quantity Order:
    Origin:
    China
    Payment Method:
    Telegraphic Transfer (T/T)

    Specification :

    Introduction
    1 cleaning
    Two-way flush function: blood chamber and the dialysis fluid chamber powerful forward and reverse flush.
    Fluctuating pressure cleaning: wash room blood pressure fluctuations, vibration plus washing to achieve the simulation results.
    Anti ultrafiltration function: reverse dialysis membrane ultrafiltration to remove plasma membrane components, reducing the effective area of loss and prolong life.
    More effective removal of residual proteins within the dialyzer and the blood.
    Oxidation clean: detergent can be used to enhance the blood stains on the dialyzer cleaning effect.

    2detection
    ; blood dialyzer reuse machine for different types of dialysis, the blood chamber design capacity and stress testing.
    1) The blood dialyzer reuse machine can determine the blood dialyzer any room capacity value, the error between the range of ± 5% .
    If the measured blood dialyzers Room Room capacity is less than the original blood volume of 80% , the test is not passed, and vice versa through.
    2) stress tests, automatic dialyzer reuse machine to each dialyzer first set a 250mmHg pressure, the test process, the observed pressure loss:
    a) ultrafiltration coefficient is less than 15 dialysis machines, within 30 seconds, if the pressure variation than 3.3kPa ( 25mmHg) , rupture of membrane dialyzer is considered, there is alarm;
    b) ultrafiltration coefficient of greater than 15 dialysis machines, within 20 seconds, if the pressure variation than 3.3kPa ( 25mmHg) , rupture of membrane dialyzer is considered, there is alarm.

    3 sterilization function
    Automatic dilution of disinfectant to prevent the draining of water. Charge pumping disinfectant and to remove air bubbles into the dialyzer, the dialysis period, full of disinfectant to ensure disinfection.
    4 alarm
    No water, poor drainage; not suck disinfectant; dialysis tubing is not connected properly; dialysis rupture; dialysis capacity is not enough.
    5 Features
    Standardization: full compliance with the Ministry of Health, " the blood dialyzer reuse practices, " the requirements.
    Advanced Technology: core technology plus American independent process innovation, anti-leak valve modular system, functional and practical and reliable.
    Flexible Interface: user-friendly interface, to achieve full Chinese display, automatic program decomposition process combined with a flexible, hands touch the keyboard, cleaning, disinfection, testing, both independent operations can be combined multiplexing, easy, practical and convenient.
    Testing correction: Automatic detection of ventricular volume and blood dialyzer membrane integrity, accurate and reliable, to ensure that reusable dialyzer reuse on dialysis patient safety.
    Open disinfectant: meet the disinfection requirements of the Ministry of Health, peracetic acid and other disinfectants are available. Reuse to reduce the cost of hemodialysis.

    6 Specifications
    Power conditions: AC220V/ 50HZ
    Environmental conditions: Temperature: 5 ~ 40 ° C, relative humidity: 10% to 80% , atmospheric pressure: 86 ~ 106KPa
    Water requirements: comply with the U.S. AAMI / ANSI standard anti-seepage, water pressure: 0.15 ~ 0.35MPa, water temperature: 10 ~ 38 ° C, the minimum water flow: 1.5L/ min
    Disinfectant: 0.3 ~ 0.4% peracetic acid, 4% formalin
    Detection range: Capacity test ( TCV) : Range 0 ~ 170ml, error of ± 5% , the pressure detection: air pressure detection, error ± 4%
    Working Hours: reuse time ( including fresh, disinfection, testing) 5 ~ 12min

    7 benefits of dialyzer reuse
    Improve the biocompatibility of dialysis membrane. Improve the biocompatibility of dialysis when the patient feel comfortable, side effects.
    Prevention of dialysis for the first time syndrome. New production of ethylene oxide sterilized dialyzer used, some patients with new dialysis treatment allergic reaction.
    Dialyzer reuse after use, to reduce the residual ethylene oxide, ethylene oxide will reduce allergic reactions.
    Save money. 5 to 20 times reuse, dialysis supplies costs can be reduced to a one-time 1 / 10.
    Conducive to environmental protection. Production of dialyzers are non-degradable materials, the material, a large number of discarded disposable dialyzers on our environment is a great burden.