Automatic Total Nitrogen Analyzer Model TNC - 250[Nov. 23, 2011 1:42:16]
PriceNN
Quantity Order:
Pack. & DeliveryUnit
OriginJapan

Specification

Automatic Total Nitrogen Model TNC - 250

- As the total nitrogen measurement process of this
analyzer is adopted with contact thermal
decomposition method for decomposition and with
chemiluminescence for detecting method, reagents
are not required for the measurement
- â Helpâ function ( software) is employed at all of
touch panel screen to give quick reference at each
operation stage, thereby, operability and
maintenance activity are improved
- Data storage capacity becomes greater because of
the adoption of CF card ( Data storage capacity is
for approx. five years of operation)
- This analyzer is applicable to the sample containing
sea water

Specification :

Name of product : Total Nitrogen Automatic Analyzer
Model : TNC-250
Measuring object : Total Nitrogen in water ( for process
surveillance and effluent monitoring)
Measuring method : Chemiluminescence
Measuring range : Optionally selectable among ranges
0~ 20, 0~ 50, 0~ 100, 0~ 500,
0~ 1000mgN/ L ( No dilution for
0~ 20mg/ L range)
Repeatability : Within + / -3% F.S. ( at span calibration
solution)
Within + / -4% F.S. in case that
dilution is used
Measuring cycle : 5 min. ~ 120min. ( optionally settable
among 5, 6, 10, 12, 15, 20, 30, 60,
120)
Measurement path : 1 flow path, 2 flow paths
Display system : Touch-screen system ( â Helpâ menu is
appeared at each screen)
Recording method : Compact flash memory is integrated,
printer having automatic rewinding
function
Calibration method : Manual calibration or automatic
calibration by calibration solution
Calibration sol. : Potassium nitrate
Consumption of Calibration Sol. : 500mL/ calibration ( in case of no
dilution and every 5 times of
measurement)
Analog output signal : 4~ 20mADC measurement value of
one flow path 2 channels,
Load resistance 600W or less