OILFLOW METER FR806C TUTHILL, DI SURABAYA
PriceTHE BEST
Quantity Order:
Payment MethodTelegraphic Transfer (T/T)
Pack. & DeliveryDOS
OriginUnited States

Specification

AGRO INDUSTRI SURABAYA
TELP. 031 60234888 , FAX. 031 3980197
WWW.AGROINDUSTRISURABAYA.COM

THANK YOU FOR YOUR TIME TO VISIT US

WE CAN SUPPLY COMPLETE RANGE OF OIL FLOW METER

PLEASE SEND INQUARY TO:
INDUSTRI2034@ GMAIL.COM

Description of Included Models

Safety Listings

Available Options
PRODUCT DATA SHEET
Series 800C Meter
z Description of Included Models
z Available Options
z Safety Listings
z Accessories
z Performance
z Flow Control
z Fluid Compatibility
z Dimensions
z Repair
z Maintenance
z Frequently Asked Questions
z Reference Literature

Model 807C Pump Shown
Model Number Description
806C Basic Meter with Strainer & Fittings with 1" Inlet & Outlet
807C Basic Meter with 3/ 4" Inlet & Outlet
807C-1 Basic Meter with 1" Inlet & Outlet
KIT 807CMK Basic 807C Meter with Pipe Fittings to Add Meter to Models 112, 122, FR152, FR162, 1210B, FR610 and
FR700
Approval
Organization Mark Organization Description File
Number
Guide
Number
Underwriters Laboratories Inc., a
nationally recognized Independent
organization for testing of products
to ensure public safety. Also
recognized and accepted in
Canada.
MH8290 PLRZ

Flow Control
Fluid Compatibility
The 800C series meters are compatible with the following fluids:
Diesel Fuel, Gasoline, Kerosene, Mineral Spirits, Heptane and Hexane.
The 800C Series meters are NOT compatible with the following fluids:
Option Description
Weight
( lbs.)
Weight
( kgs.)
L Liter Registration in Place of Standard Gallon Measure - -
N Nickel Plating on Fluid Handling Components - -
Q Basic Meter with EPDM Seals - -
T Teflon Coating on Fluid Handling Components - -
Part Number Description
TH18T Strainer Kit for Mounting Series 800C Meter on an Overhead Tank
TH18T Teflon Coated Strainer Kit for Mounting Series 800C Meter on an Overhead Tank
Recommended Flow Range 5 to 20 GPM ( 19 to 76 LPM)
Rated Accuracy ± 1%
Maximum Pressure 50 PSIG
Meter Digit Indication Up to 99.9 Gallons or 999.9 Liters ( Resettable)
Totalizer Digit Indication Up to 99, 999.9 Gallons or Liters ( Non-Resettable)
A. This curve represents the expected pressure loss
through the Model 800 Meter as a function of flow. Any
pump used in the system must supply not only the
pressure required to move the fluid, but also that
required to overcome the pressure drop through the
meter.
Page 2 of 5
Bleach, Hydrochloric Acid, Ink, Motor Oil and Salt Water.
If in doubt about the compatibility of a specific fluid, contact the supplier of the fluid to check for any adverse reactions
to the following wetted materials.

Repair
To insure the ultimate performance, pumps must be set up according to the " INSTALLATION" section of the Owner' s
Manual packed with the pump and available below in the Reference Literature section.
Meters requiring repair should be taken to an authorized repair shop or returned to the factory for service. Meters MUST
be thoroughly triple-rinsed before being taken in, or shipped, for repair.

Ryton 300S Stainless Steel 400S Stainless Steel All
Aluminum 806C, 806CL, 806CI, 807C, 807CL, 807CI, 807C-1, 807CL-1, 807CI-1
Aluminum, Nickel Plated 807CN , 807CN-1, 807CNL
Aluminum, Teflon Coated 806CT, 806CTL, 807CT, 807CT-1, 807CTL-1
Viton 806C, 806CT, 806CL, 806CTL, 806CI, 807C, 807CN, 807CT, 807CL, 807C-1,
807CN-1, 807CT-1, 807CL-1, 807CNL-1, 807CTL-1, 807CI-1
Buna N 806C, 806CL, 806CI, 807C, 807CL, 807C-1, 807CL-1, 807CI-1
EPDM 806CQ, 807CQ
Cast Iron 806C, 806CT, 806CL, 806CLT, 806CI
Page 3 of 5
Maintenance
Meters are designed to operate maintenance free. Certain liquids can dry out while in the meter housing, preventing the
meter from operating properly when next used. If this happens, the meter should be thoroughly cleaned by running a
flushing fluid through the meter in the normal direction of fluid flow, without disassembly. If fluid cannot be " forced" through
the meter with 50 PSIG fluid pressure and thus freed, the meter must be disassembled and thoroughly cleaned. Refer to
the instructions in the ASSEMBLY/ DISASSEMBLY section of the Parts and Technical Service Guide that was packed with
your meter or is available below in the Reference Literature section for the procedure.

Frequently Asked Questions
The questions below are linked to the answers for that particular question. Point and click on the question of interest and
you will be move to the answer to that question. Buttons are provided to allow you to move back to this question list or to
the original INDEX.
1. When I went to use my meter for the first time this year it was stuck. What can I do?
2. Can I use this material to sell kerosene from my tank?
3. What do you mean by a " positive displacement meter?
4. How can I be sure my meter is operating properly?
5. What limits the flow capacity of this meter?
1.When I went to use my meter for the first time this year it was stuck. What can I do?
Although your meter is designed to require little or no maintenance, the residual material left when a fluid dries in the
meter can jam the close tolerance disc within the chamber. See the procedure recommended for cleaning the meter above
and in the Guide referenced below and packed with the meter. Generally a thorough cleaning will restore the meter to full
operation.

2. Can I use this meter to sell kerosene from my tank?
This meter mechanism is capable of high accuracy, typically 0.5% , if operated under steady flow rate and calibrated at
that rate. This capability however does not meet the requirements of the Weights and Measures Departments in most
states and they therefore will not approve this meter for use for the resale of liquids like kerosene.
See the Troubleshooting Guide in your Owner' s Manual packed with your unit or the copy available " on-line" in the
Reference Documents section of this More Info page for things to check.

3. What do you mean by a " positive displacement meter?
A positive displacement meter allows a VERY specific volume of fluid to move through the meter with every rotation of the
mechanism. Conversely if the mechanism of a positive displacement meter is held, there should be no flow through the
meter. That VERY specific volume is determined by the designed size of the meter chamber and allows the rotating meter
shaft to be tied to a counter which indicates the count of rotations as the volume of fluid passing through the meter. By
varying the gear ratio tying the chamber to the counter, the same chamber can be used for two different units of measure,
like gallons and liters.

Page 4 of 5
4. How can I be sure my meter is operating properly?
After zeroing the meter, fill a container of known volume and compare the indicated volume to the measured volume. As
simple as this method seems it is used universally as the absolute calibration means by all requiring accurate meter
indication. A container used for this type calibration is described as a " proving can" and the use of a proving can 5X the
major unit of calibration is recommended. In the case of the 800 meter, where gallon is the most common unit of measure,
a five gallon proving can is recommended and generally can be obtained from the dealer where your meter was
purchased.

5. What limits the flow capacity of this meter?
AThe forced flow of fluid through the meter results in a pressure differential measured across the meter, and the higher
the flow through the meter, the higher that pressure drop across the meter. While the increase in pressure drop is close to
linear with the increase of flow over a considerable range, that linearity is lost at the upper flow levels because of the
physical size of the chamber and the ports into and out of the chamber. The upper limit where that linearity is lost is
normally taken as the upper flow limit of allowed operation. In the case of the 800C that flow level is 20 GPM.
[ back to data sheet index] ]
Reference Literature

To view the following document a copy of Acrobat® Reader must be installed on your computer. If you have
not already done so, follow the link on the right to download a free copy.
800C Meter Parts and Technical Service Guide - This is the full document that is packed with meter when shipped from
the factory.

Best Regards,
RAHMAT HIDAYAT
081230777817

Update on : 14 / 02 / 12

showing 3 of 75