Welcome to
Penghemat Listrik | CV. CBS
Company Contact | ||
---|---|---|
Name: | Mr. Heri [Director/CEO/General Manager] | |
E-mail: | Send Message | |
Instant Messaging: | ||
Mobile Number: | ||
Phone Number: | ||
Address: | Jl. Joglo Raya No. 75, Joglo Jakarta Barat 11640, Jakarta Indonesia | |
Average User Review | There is no review for this company - Write a review | |
Registration Date: | May. 24, 2023 | |
Last Updated: | Apr. 5, 2011 | |
Business Nature: | Trade, Service of Electronics & Electrical category | |
Want to contact this company?
| ||
Put on Company Partner | ||
Recommend to your friends | ||
Company Brief | ||
Saving Electricity TOP Saver or Energy Saver ( Penghemat Listrik) I. INTRODUCTION Scarce natural resources to produce energy, particularly electrical energy to make us aware of the importance of energy conservation both government and private sector. To enhance competitiveness in producing goods, industrial sector secara terus constantly trying to look for efficiency measures, especially those relating directly at a cost of production, one of which cost dimana listrik energy consumption of electrical energy costs is an element of fixed costs yang during this very difficult to do efficiency. Know that actually realized or not any electrical equipment either within the household, buildings, factories and others who use a coil of an induction coil is the source of ( pseudo power) . Where this induction resulted in greater force than necessary giving rise to increased power and cost of course. On the basis that we are from CV. Cakra Buana Sejahtera provides a solution to this problem, we introduce a tool that serves Top Saver eliminates induction by improving power quality ( power quality improvement) that will automatically reduce unnecessary costs. Top Saver background so that we produce is hopefully useful for all of us. Sincerely CV. Cakra Buana Sejahtera II. TOP Saver or Energy Saver 1. Top Saver or Energy Saver is one type of capacitor bank which has developed its technology as a means of compensators / compensating Losses Reduction ( CLR) , which can improve power factor and is able mengefesienkan electricity usage, working in Full Automatic. Because the appliance is equipped with automatic controls that work based on the minimum amperes, with the understanding to work upon use of ( maximum amperes) and vice versa does not work when using a small ( minimum amperes) . 2. Technical Characteristics of Top Saver or Energy Saver Improving Power Factor ( Cos phi) Curent Reducing Energy Losses by 30% . Improving the ratio of Active Power ( kw) and the Real Power ( kVA) Reduce heat to a phase so there is no overload Improving the current and voltage angle Reduces Total Harmonic Distortion ( THD) 3. Electrical power can be saved by the Top Energy Saver or Saver include: - A refrigerator ( freezer, refrigerator, ac, cheeler) - Water Pumps - Neon Lamp / PLS / TL - Computers - Lifts - Refrigerator - Electric motor - All electrical equipment that uses coil / coil) Etc. 4. Technical specifications Top Saver or Energy Saver V 220 Expenses Panel Box with thermoplastics materials, Plate Automatic Control Unit Mini contractors telemekanik Terminal 3p, 4p and 6p 220 volt pilot lamp Assembling materials. 5. Top Saver or Energy Saver is ideal for networks with an installed capacity of three phases as follows: 6. 600 va, va 10 500, 13 200 va, 16. Va 500, 23 000 va, va 33 000, 41 500 va, va 53 000, 66 000 va, va 82 500, and 100 kVA up to mega-va. III. TOP ADVANTAGES Saver or Energy Saver 1. Save on electric bills up to 10-30% This tool works well fluctuating or constant usage, because the savings are real power ( kw) of electricity consumption costs. 2. Improve efficiency by eliminating power losses that have a direct impact on the reduction of electricity bills. With the loss of power losses in the electricity network there will be improvement in the quality or expense happening efficiency of the use of electrical power so that a linear reduction in electricity bills ( kwh) or the savings can be used as spare capacity to add equipment without having to add power from PLN. 3. Extend the life of electrical equipment The result of improvements in the quality of load power to produce electrical work in accordance with the required power levels so that the life of electrical equipment more durable. 4. Memperebaiki distribution from source to load Are installed near the load line Saver ( perpanel distribution) then the distance from the source to the load is not a problem and hence reducing wasted power levels, all received load power in accordance with the power needed and can prevent the occurrence of Overloading ( excessive heat in the cable network that could result fire risk) . 5.Kapasitas this tool will be adjusted by the amount of installed power. 6. Use up to 90 000 hours or 10 years 7. Materials made of thermoplastic material Waterproof, Plate Material is resistant to water and is not electrically conductive ( having the character of conductor) . 8. Safe and environmentally friendly Because the tool is working on a parallel distribution system and will not cause pollution which disturb the environment. IV. TOP SYSTEM INSTALLATION Saver or Energy Saver Top Saver Fitting was done by several systems including the following: 1. Top Saver System on a network installation of the completed capacitor bank. Technology conventional compensator capacitor bank is widely used in industrial electrical systems, benefit from its use purely to eliminate excess kVAR kVAR or fines. In use the average energy capacitor bank is still causing losses, 0.5 to 2% , this is caused by a wiring system ( Phase phase) resulting in heat. In some applications Top Saver as compensator has been proven capable of improving the ratio of Active Power and Real Power, for Top Saver can improve voltage and current angle to a certain extent that can not be done by the capacitor bank. Profit earned on the network who have used the capacitor bank is able to increase the Life Time capacitor bank. 2. System installation at each distribution panel or main panel. Top Saver is to connect each main distribution panel or panels in parallel. And if the load change at any time change its Top Saver adjust for these changes, it will not happen over-compensating the capacitive load will cause because of wiring systems Phase with Neutral ( RN) ( SN) and ( TN) V. INSTALLATION PROCEDURES TOP Saver or Energy Saver 1. Location and Cost Survey Survey locations and charges made to ensure the effectiveness of the installation, the number of units and the capacity to be installed. 2. On The Spot Test Top Saver by using the Power Analyzer to see whether or not the tool is installed. and at the Test On The Spot can be seen directly the result of saving Real Power ( kw) . The survey results are made will be attached at the time of bidding price. 3. Standardization Fitting Top Saver or Energy Saver Top Saver is installed in parallel in the main distribution panel or panels to obtain maximum savings are strongly encouraged to install this tool on the distribution per panel Companies or institutions that have installed Saver or Energy Saver TOP - Workshop Rado ( Raden Intan East Jakarta) . Capacity 16 500 VA - Carriage House ( Jl. Ciputat Raya No. 40 Jak-Cell) . Capacity 41 500 VA - JAMSOSTEK Cab Office. Majalaya ( Jl. Soekarno-Hatta, Bandung) . Capacity 16 500 VA - Lagunas Restaurants Istora Senayan. Capacity 33 000 VA - Adhi Jaya Hotel Bali. Installed power 150 KVA Panel I - Motor Repair Kahf ( Jl. Raden Inten No. 61a) . Capacity 10 600 VA - General Store Borma Kopo Park Indah Bandung. Installed power 105 KVA - And many more whose data we collect is not Survey costs Rp. 100 000 for the region Bodetabek If you are interested can contact: Heri: 081281502326 02171524463 Email: @ yahoo.com energi.saver | ||
|
You have [3] new inquiries. Go to Member Menu Home - Trade List - Product List - Inquiry List - Cooperation List - Company List Copyright © 2024 Indotrade.co. All Rights Reserved. |