PULSE Total Station Topcon( REFLECTORLESS) GPT-3002N, PULSE Total Station Topcon( REFLECTORLESS) GPT-3002LN/ N, PULSE Total Station Topcon( REFLECTORLESS) GPT-3005LN/ N, PULSE Total Station Topcon( REFLECTORLESS) GPT-3007LN/ N[Dec. 13, 2009 22:22:08]
PriceNegosiasi
Quantity Order: Add to Basket
Payment MethodTelegraphic Transfer (T/T), Cashier Order
Pack. & DeliverySet
OriginJapan
Specification
PULSE Total Station Topcon( REFLECTORLESS) GPT-3002N, PULSE Total Station Topcon( REFLECTORLESS) GPT-3002LN/ N, PULSE Total Station Topcon( REFLECTORLESS) GPT-3005LN/ N, PULSE Total Station Topcon( REFLECTORLESS) GPT-3007LN/ N

PULSE Total Station Topcon( REFLECTORLESS) GPT-3002N
* Telescope: ?
Length : 150 Millimeters
Objective lens Diameter : 45mm ( ED: 50mm)
Magnification : 30X
Image : Erect
Field of view : 1° 30
Resolve power : 2.8"
Min. Focus Distance : 1.3 meters
* Measurement range
1 Prism : 3, 000 meters ( 9, 900ft)
Mini Prism : 1000 meters ( 3, 280ft)
Non-Prism mode : 1.5-350m ( 5-1148ft)
* Measuring accuracy
- Prism Mode
± ( 2mm+ 2ppmxD* ) m.s.e. fine,
± ( 7mm+ 2ppmxD* ) m.s.e. coarse
- Non-prism mode
± ( 3mm+ 2ppm) m.s.e. fine,
± ( 10mm) m.s.e. coarse
- Minimum reading
0.2mm( 0.001ft.) / 1mm( 0.005ft) fine,
1mm( 0.005ft) / 10mm( 0.02ft.) coarse,
10mm( 0.02ft.) tracking
- Measurement time
1mm: 1.1 sec.( Initial 2.5 sec.) fine
0.2mm: 1.5 sec ( Initial 3.0 sec.) fine
0.8 sec.( Initial 2.5 sec.) coarse
0.5 sec.( Initial 2.5 sec.) tracking
- Measurement time ( non prism)
( up to 100m. At longer distance and/ or poor reflective surface? time will be longer)
1mm: 1.7 sec.( Initial 3.0 sec.) fine
0.2mm: 2.6 sec ( Initial 3.5 sec.) fine
1.0 sec.( Initial 2.0 sec.) coarse
0.4 sec.( Initial 2.0 sec.) tracking
* Angle measurement
Method : Absolute
Detection:
GPT-3102N : 2 sides horizontal, ? 2 sides vertical
Minimum reading:
GPT-3102N : 1" / 5" arc sec, 0.2/ 1 mgon
Accuracy:
GPT-3102N : 2" arc sec ( 0.6 mgon)
Diameter of circle : 71 Millimeters
* ? Tilt correction
Type : Single or Dual Axis ( GPT-3107N: single)
Compensating : ± 3
Range correction unit : 1" arc sec, 0.1 mgon
* Environmental?
Circular level sensitivity : 10 / 2mm
Plate level sensitivity : 30" / 2mm/ 40 / 2mm ( GPT-3107N)
Optical plummet3x Magnification,
0.5m to infinity Focusing Range,
Erect Image, 5° Field of View
Laser pointer ? LD ( Visible Laser) light source,
690nm wave length,
1mW Maximum output,
Class 2 ( IE Publication 825)
Class II ( FDA/ BHR 21 CFR 1040) class
Dimensions ( HxWxL) 336( H) x 184( W) x 174( L) mm
13.2( H) x 7.2( W) ? x 6.9( L) inches
Instrument Weight ( with battery) : 5.3 kg ( 11.6 lbs)
Case weight : 3.4 kg ( 7.5 lbs)
Dust/ Water protection : IP66 rating
Operating temperature : -20° to + 50° Celsius, -4° to + 122° Fahrenheit
* Power
Source : NiMH Battery BT-52QA
Output voltage : DC 7.2? volts
Capacity : 2700mAh
Approximate battery life ( when fully charged at 20° C ) : 5.0 hours including distance measurement, 45 hours Angle measurement only
* ? Battery Charger
ID : BC-27
Input Voltage : AC100-240 Volts
Frequency : 50/ 60 Hertz
Recharging Time : 1.8 hours
Operating temperature : + 10° to + 40° Celcius, + 50° to + 104° Fahrenheit

PULSE Total Station Topcon( REFLECTORLESS) GPT-3002LN/ N
Telescope
- Length : 150mm
- Objective Lens Diameter : 45mm ( EDM 50mm)
- Magnification : 30x
- Image : Erect
- Field of View : 1° 30'
- Resolving Power : 2.8"
- Min.Focus Distance : 1.3m ( 4.9ft)
Distance Measurement
= Prism Mode :
- Measuring Range ( 1 prism) : 3, 000m
= Condition 1: Slight haze with visibility about 20km ( 12.5miles) moderate sunlight with light heat shimmer.
- Measurement accuracy : :
> Fine : + / -( 3mm+ 2ppm) m.s.e.
> Coarse: + / -( 7mm+ 2ppm) m.s.e.
Non Prism Mode ( Diffusing Surface)
- Measuring Range : 1.5m to 250m
- Measuring Accuracy :
> Fine Mode : + / -( 5mm) m.s.e. ( 25m or more)
> ' + / -( 10mm) m.s.e. ( 1.5-25m)
> Coarse : + / -( 10mm) m.s.e.
- Measuring Time :
> Fine 1mm mode : Approx 1.2sec ( Initial 3sec)
> Fine 0.2mm mode: Approx 3.0sec ( Initial 4sec)
> Coarse mode 1mm/ 10mm : Approx 0.5sec ( initial 2.5sec)
Non Prism Long Mode ( Diffusing Surface)
- Measuring Range : 5m to 1, 200m
- Measuring Accuracy
( + / -( 10mm+ 10ppm) m.s.e.
> Coarse 5/ 10mm : + / -( 20mm+ 10ppm) m.s.e.
> Tracking ( 10mm) mode : + / -( 100mm) m.s.e.
- Measuring Time :
> Fine 1mm mode : Approx 1.5 to 6sec ( Initial 6-8sec)
> Coarse mode ( 5/ 10mm) : Approx 1 to 3 sec ( Initial 6 to 8sec)
> Tracking ( 10mm) mode : Approx 0.4sec ( Initial 4 to 7 sec)
= Least Count in Measurement
- Prism Mode / Non Prism Mode :
> Fine Mode 1mm / 0.2mm
> Coarse Mode : 10mm/ 1mm
- Non Prism Long Mode :
> Fine Mode : 1mm
> Coarse Mode : 5mm/ 10mm
> Tracking Mode : 10mm
= Others
- Measurement Display : 12digits : max display 99999999.9999
- Atmospheric Correction Range : -999.9ppm to + 999.9ppm, in 0.1ppm increments
- Prism Constant Correction Range : -99.9mm to + 99.9mm, in 0.1mm increments
= Angle Measurement
- Method : Absolute Reading
- Detecting System :
> H: 2sides
> V: 2sides
- Minimum Reading : 1" / 5" ( 0.2/ 1mgon)
- Accuracy : 2" ( 0.6mgon)
- Measuring Time : Less than 0.3sec
- Diameter of Circle : 71mm
= Display
- Display Unit :
> Graphics LCD 160x64 dots with backlight
> 2sides
- Keyboard : Alpha-Numeric Key
= Tilt Correction ( Automatic Index)
- Tilt Sensor : Dual Axis
- Method : Liquid type
- Compensating Range : + / -3'
- Correction Unit : 1" ( 0.1mgon)
- Others : Others
- Data Recording ( Memory) : Approx 24, 000 points
- Instruments Heights : 176mm ( 6.93in)
- Laser Class
> Class 1 ( for distance measurement)
> Class 2 ( Laser Pointer : On/ Off Switchable)
= Level Sensitivity
- Circular Level : 10" / 2mm
- Plate Level : 20" / 2mm
= Size / Weight
- Dimention : 336( H) x184( W) x172( L) mm
- Weight
> Instrument ( with battery) : 5.3kgs
> Plastic Carrying Case : 3.4kgs ( Slightly different depending on market)
= Durability
- Water & Dustproof : IP66 ( incl BT-52QA battery) ( Based on the standard IEC60529)
- Ambient Temperature Range : -20? C to + 50? C
= Battery BT-52Q
- Output Voltage : DC7.2V
- Capacity : 2.7Ah ( Ni-MH)
- Maximum Operating time ( when fully recharged) at + 20? C : Maximum Operating time ( when fully recharged) at + 20? C
- Distance+ Angle Measurement
> GPT-3000LNseries : 3.5hours
> GPT-3000N series : 4.2hours
- Angle Measurement Only : 45hours
- Weight : 0.3kg
= Battery Charger BC-27
- Input Voltage : AC100-220V
- Frequency : 50/ 60Hz
- Recharging time ( at + 20? C) : 1.8hours ( for BT-52QA battery)
- Discharging Time ( at + 20? C) : 8hours ( for BT-52QA battery fully charged)
- Operating Temperature : + 10° C to + 40° C
- Weight : 0.5kg

PULSE Total Station Topcon( REFLECTORLESS) GPT-3003LN/ N
Telescope
- Length : 150mm
- Objective Lens Diameter : 45mm ( EDM 50mm)
- Magnification : 30x
- Image : Erect
- Field of View : 1° 30'
- Resolving Power : 2.8"
- Min.Focus Distance : 1.3m ( 4.9ft)
Distance Measurement
= Prism Mode :
- Measuring Range ( 1 prism) : 3, 000m
= Condition 1: Slight haze with visibility about 20km ( 12.5miles) moderate sunlight with light heat shimmer.
- Measurement accuracy : :
> Fine : + / -( 3mm+ 2ppm) m.s.e.
> Coarse: + / -( 7mm+ 2ppm) m.s.e.
Non Prism Mode ( Diffusing Surface)
- Measuring Range : 1.5m to 250m
- Measuring Accuracy :
> Fine Mode : + / -( 5mm) m.s.e. ( 25m or more)
> ' + / -( 10mm) m.s.e. ( 1.5-25m)
> Coarse : + / -( 10mm) m.s.e.
- Measuring Time :
> Fine 1mm mode : Approx 1.2sec ( Initial 3sec)
> Fine 0.2mm mode: Approx 3.0sec ( Initial 4sec)
> Coarse mode 1mm/ 10mm : Approx 0.5sec ( initial 2.5sec)
Non Prism Long Mode ( Diffusing Surface)
- Measuring Range : 5m to 1, 200m
- Measuring Accuracy
( + / -( 10mm+ 10ppm) m.s.e.
> Coarse 5/ 10mm : + / -( 20mm+ 10ppm) m.s.e.
> Tracking ( 10mm) mode : + / -( 100mm) m.s.e.
- Measuring Time :
> Fine 1mm mode : Approx 1.5 to 6sec ( Initial 6-8sec)
> Coarse mode ( 5/ 10mm) : Approx 1 to 3 sec ( Initial 6 to 8sec)
> Tracking ( 10mm) mode : Approx 0.4sec ( Initial 4 to 7 sec)
= Least Count in Measurement
- Prism Mode / Non Prism Mode :
> Fine Mode 1mm / 0.2mm
> Coarse Mode : 10mm/ 1mm
- Non Prism Long Mode :
> Fine Mode : 1mm
> Coarse Mode : 5mm/ 10mm
> Tracking Mode : 10mm
= Others
- Measurement Display : 12digits : max display 99999999.9999
- Atmospheric Correction Range : -999.9ppm to + 999.9ppm, in 0.1ppm increments
- Prism Constant Correction Range : -99.9mm to + 99.9mm, in 0.1mm increments
= Angle Measurement
- Method : Absolute Reading
- Detecting System :
> H: 2sides
> V: 1sides
- Minimum Reading : 1" / 5" ( 0.2/ 1mgon)
- Accuracy : 3" ( 1mgon)
- Measuring Time : Less than 0.3sec
- Diameter of Circle : 71mm
= Display
- Display Unit :
> Graphics LCD 160x64 dots with backlight
> 2sides
- Keyboard : Alpha-Numeric Key
= Tilt Correction ( Automatic Index)
- Tilt Sensor : Dual Axis
- Method : Liquid type
- Compensating Range : + / -3'
- Correction Unit : 1" ( 0.1mgon)
- Others : Others
- Data Recording ( Memory) : Approx 24, 000 points
- Instruments Heights : 176mm ( 6.93in)
- Laser Class
> Class 1 ( for distance measurement)
> Class 2 ( Laser Pointer : On/ Off Switchable)
= Level Sensitivity
- Circular Level : 10" / 2mm
- Plate Level : 20" / 2mm
= Size / Weight
- Dimention : 336( H) x184( W) x172( L) mm
- Weight
> Instrument ( with battery) : 5.3kgs
> Plastic Carrying Case : 3.4kgs ( Slightly different depending on market)
= Durability
- Water & Dustproof : IP66 ( incl BT-52QA battery) ( Based on the standard IEC60529)
- Ambient Temperature Range : -20? C to + 50? C
= Battery BT-52Q
- Output Voltage : DC7.2V
- Capacity : 2.7Ah ( Ni-MH)
- Maximum Operating time ( when fully recharged) at + 20? C : Maximum Operating time ( when fully recharged) at + 20? C
- Distance+ Angle Measurement
> GPT-3000LNseries : 3.5hours
> GPT-3000N series : 4.2hours
- Angle Measurement Only : 45hours
- Weight : 0.3kg
= Battery Charger BC-27
- Input Voltage : AC100-220V
- Frequency : 50/ 60Hz
- Recharging time ( at + 20? C) : 1.8hours ( for BT-52QA battery)
- Discharging Time ( at + 20? C) : 8hours ( for BT-52QA battery fully charged)
- Operating Temperature : + 10° C to + 40° C
- Weight : 0.5kg

PULSE Total Station Topcon( REFLECTORLESS) GPT-3005LN/ N
Telescope
- Length : 150mm
- Objective Lens Diameter : 45mm ( EDM 50mm)
- Magnification : 30x
- Image : Erect
- Field of View : 1° 30'
- Resolving Power : 2.8"
- Min.Focus Distance : 1.3m ( 4.9ft)
Distance Measurement
= Prism Mode :
- Measuring Range ( 1 prism) : 3, 000m
= Condition 1: Slight haze with visibility about 20km ( 12.5miles) moderate sunlight with light heat shimmer.
- Measurement accuracy : :
> Fine : + / -( 3mm+ 2ppm) m.s.e.
> Coarse: + / -( 7mm+ 2ppm) m.s.e.
Non Prism Mode ( Diffusing Surface)
- Measuring Range : 1.5m to 250m
- Measuring Accuracy :
> Fine Mode : + / -( 5mm) m.s.e. ( 25m or more)
> ' + / -( 10mm) m.s.e. ( 1.5-25m)
> Coarse : + / -( 10mm) m.s.e.
- Measuring Time :
> Fine 1mm mode : Approx 1.2sec ( Initial 3sec)
> Fine 0.2mm mode: Approx 3.0sec ( Initial 4sec)
> Coarse mode 1mm/ 10mm : Approx 0.5sec ( initial 2.5sec)
Non Prism Long Mode ( Diffusing Surface)
- Measuring Range : 5m to 1, 200m
- Measuring Accuracy
( + / -( 10mm+ 10ppm) m.s.e.
> Coarse 5/ 10mm : + / -( 20mm+ 10ppm) m.s.e.
> Tracking ( 10mm) mode : + / -( 100mm) m.s.e.
- Measuring Time :
> Fine 1mm mode : Approx 1.5 to 6sec ( Initial 6-8sec)
> Coarse mode ( 5/ 10mm) : Approx 1 to 3 sec ( Initial 6 to 8sec)
> Tracking ( 10mm) mode : Approx 0.4sec ( Initial 4 to 7 sec)
= Least Count in Measurement
- Prism Mode / Non Prism Mode :
> Fine Mode 1mm / 0.2mm
> Coarse Mode : 10mm/ 1mm
- Non Prism Long Mode :
> Fine Mode : 1mm
> Coarse Mode : 5mm/ 10mm
> Tracking Mode : 10mm
= Others
- Measurement Display : 12digits : max display 99999999.9999
- Atmospheric Correction Range : -999.9ppm to + 999.9ppm, in 0.1ppm increments
- Prism Constant Correction Range : -99.9mm to + 99.9mm, in 0.1mm increments
= Angle Measurement
- Method : Absolute Reading
- Detecting System :
> H: 2sides
> V: 1sides
- Minimum Reading : 1" / 5" ( 0.2/ 1mgon)
- Accuracy : 5" ( 1.5mgon)
- Measuring Time : Less than 0.3sec
- Diameter of Circle : 71mm
= Display
- Display Unit :
> Graphics LCD 160x64 dots with backlight
> 2sides
- Keyboard : Alpha-Numeric Key
= Tilt Correction ( Automatic Index)
- Tilt Sensor : Dual Axis
- Method : Liquid type
- Compensating Range : + / -3'
- Correction Unit : 1" ( 0.1mgon)
- Others : Others
- Data Recording ( Memory) : Approx 24, 000 points
- Instruments Heights : 176mm ( 6.93in)
- Laser Class
> Class 1 ( for distance measurement)
> Class 2 ( Laser Pointer : On/ Off Switchable)
= Level Sensitivity
- Circular Level : 10" / 2mm
- Plate Level : 20" / 2mm
= Size / Weight
- Dimention : 336( H) x184( W) x172( L) mm
- Weight
> Instrument ( with battery) : 5.3kgs
> Plastic Carrying Case : 3.4kgs ( Slightly different depending on market)
= Durability
- Water & Dustproof : IP66 ( incl BT-52QA battery) ( Based on the standard IEC60529)
- Ambient Temperature Range : -20? C to + 50? C
= Battery BT-52Q
- Output Voltage : DC7.2V
- Capacity : 2.7Ah ( Ni-MH)
- Maximum Operating time ( when fully recharged) at + 20? C : Maximum Operating time ( when fully recharged) at + 20? C
- Distance+ Angle Measurement
> GPT-3000LNseries : 3.5hours
> GPT-3000N series : 4.2hours
- Angle Measurement Only : 45hours
- Weight : 0.3kg
= Battery Charger BC-27
- Input Voltage : AC100-220V
- Frequency : 50/ 60Hz
- Recharging time ( at + 20? C) : 1.8hours ( for BT-52QA battery)
- Discharging Time ( at + 20? C) : 8hours ( for BT-52QA battery fully charged)
- Operating Temperature : + 10° C to + 40° C
- Weight : 0.5kg

PULSE Total Station Topcon( REFLECTORLESS) GPT-3007LN/ N
Telescope
- Length : 150mm
- Objective Lens Diameter : 45mm ( EDM 50mm)
- Magnification : 30x
- Image : Erect
- Field of View : 1° 30'
- Resolving Power : 2.8"
- Min.Focus Distance : 1.3m ( 4.9ft)
Distance Measurement
= Prism Mode :
- Measuring Range ( 1 prism) : 3, 000m
= Condition 1: Slight haze with visibility about 20km ( 12.5miles) moderate sunlight with light heat shimmer.
- Measurement accuracy : :
> Fine : + / -( 3mm+ 2ppm) m.s.e.
> Coarse: + / -( 7mm+ 2ppm) m.s.e.
Non Prism Mode ( Diffusing Surface)
- Measuring Range : 1.5m to 250m
- Measuring Accuracy :
> Fine Mode : + / -( 5mm) m.s.e. ( 25m or more)
> ' + / -( 10mm) m.s.e. ( 1.5-25m)
> Coarse : + / -( 10mm) m.s.e.
- Measuring Time :
> Fine 1mm mode : Approx 1.2sec ( Initial 3sec)
> Fine 0.2mm mode: Approx 3.0sec ( Initial 4sec)
> Coarse mode 1mm/ 10mm : Approx 0.5sec ( initial 2.5sec)
Non Prism Long Mode ( Diffusing Surface)
- Measuring Range : 5m to 1, 200m
- Measuring Accuracy
( + / -( 10mm+ 10ppm) m.s.e.
> Coarse 5/ 10mm : + / -( 20mm+ 10ppm) m.s.e.
> Tracking ( 10mm) mode : + / -( 100mm) m.s.e.
- Measuring Time :
> Fine 1mm mode : Approx 1.5 to 6sec ( Initial 6-8sec)
> Coarse mode ( 5/ 10mm) : Approx 1 to 3 sec ( Initial 6 to 8sec)
> Tracking ( 10mm) mode : Approx 0.4sec ( Initial 4 to 7 sec)
= Least Count in Measurement
- Prism Mode / Non Prism Mode :
> Fine Mode 1mm / 0.2mm
> Coarse Mode : 10mm/ 1mm
- Non Prism Long Mode :
> Fine Mode : 1mm
> Coarse Mode : 5mm/ 10mm
> Tracking Mode : 10mm
= Others
- Measurement Display : 12digits : max display 99999999.9999
- Atmospheric Correction Range : -999.9ppm to + 999.9ppm, in 0.1ppm increments
- Prism Constant Correction Range : -99.9mm to + 99.9mm, in 0.1mm increments
= Angle Measurement
- Method : Absolute Reading
- Detecting System :
> H: 1sides
> V: 1sides
- Minimum Reading : 5" / 10" ( 1/ 2mgon)
- Accuracy : 7" ( 2 mgon)
- Measuring Time : Less than 0.3sec
- Diameter of Circle : 71mm
= Display
- Display Unit :
> Graphics LCD 160x64 dots with backlight
> 1sides
- Keyboard : Alpha-Numeric Key
= Tilt Correction ( Automatic Index)
- Tilt Sensor : Single Axis
- Method : Liquid type
- Compensating Range : + / -3'
- Correction Unit : 1" ( 0.1mgon)
- Others : Others
- Data Recording ( Memory) : Approx 24, 000 points
- Instruments Heights : 176mm ( 6.93in)
- Laser Class
> Class 1 ( for distance measurement)
> Class 2 ( Laser Pointer : On/ Off Switchable)
= Level Sensitivity
- Circular Level : 10" / 2mm
- Plate Level : 40" / 2mm
= Size / Weight
- Dimention : 336( H) x184( W) x172( L) mm
- Weight
> Instrument ( with battery) : 5.3kgs
> Plastic Carrying Case : 3.4kgs ( Slightly different depending on market)
= Durability
- Water & Dustproof : IP66 ( incl BT-52QA battery) ( Based on the standard IEC60529)
- Ambient Temperature Range : -20? C to + 50? C
= Battery BT-52Q
- Output Voltage : DC7.2V
- Capacity : 2.7Ah ( Ni-MH)
- Maximum Operating time ( when fully recharged) at + 20? C : Maximum Operating time ( when fully recharged) at + 20? C
- Distance+ Angle Measurement
> GPT-3000LNseries : 3.5hours
> GPT-3000N series : 4.2hours
- Angle Measurement Only : 45hours
- Weight : 0.3kg
= Battery Charger BC-27
- Input Voltage : AC100-220V
- Frequency : 50/ 60Hz
- Recharging time ( at + 20? C) : 1.8hours ( for BT-52QA battery)
- Discharging Time ( at + 20? C) : 8hours ( for BT-52QA battery fully charged)
- Operating Temperature : + 10° C to + 40° C
- Weight : 0.5kg

We also provide service, calibration, replacement for all type sperpart Total Station

We serve orders from all over Indonesia. Shipping cost vary depending on destination. Please message the product and then do a confirmation via email / tel / chat online. ( For the Jakarta area free postage! )
Rosi Ardiansah
Hp: 085710474131
Phone: 021-28808766
Email: rosiardiansah@ gmail.com
Chat Online: rosiardiansah@ yahoo.co.id
Chat Online: rosiardiansah