Welcome to
MITECH INSTRUMENTS INDONESIA

Free Member
MITECH INSTRUMENTS INDONESIA
MITECH INSTRUMENTS INDONESIA
Indonesia
  • Products Catalog

    MITECH Ultrasonic Flaw Detector MFD350B

    MITECH Ultrasonic Flaw Detector MFD350B

    Quantity Order:
    Origin:
    China
    Payment Method:
    Telegraphic Transfer (T/T)

    Specification :

    Display :
    Hi-resolution ( 320Ã 240 pixels) multi-color TFT LCD with 4 user-selectable brightness control provides high contrast viewing of the waveform from bright, direct sunlight to complete darkness.
    The hi-resolution multi-color TFT LCD display with fast 60 Hz update gives an â analog lookâ to the waveform providing detailed information that is critical in many applications including nuclear power plant inspections.
    Range :
    Up to 6000 mm in steel. suitable for use on large work pieces and in
    high-resolution measurements.
    Pulser :
    Pulse Energy selectable among Low, Medium and High.
    Pulse Repetition Frequency adjustable from 10 Hz to 1 KHz in 1 Hz increments.
    Damping selectable among 100©  200© and 400© for optimum probe
    performance
    Test Modes include Pulse echo, dual and thru-transmission
    Receiver :
    Sampling 10 digit AD Converter at the sampling speed of 160 MHz
    Rectification Positive Halfwave, Negative Halfwave, Fullwave and RF
    Analog Bandwidth: 0.5MHz to 10MHz capability with selectable frequency
    ranges ( automatically set by the instrument) to match probe for optimum
    performance.
    Gain 0 dB to 110 dB adjustable in selectable steps 0.1 dB, 2 dB, 6 dB, and locked.
    Gates :
    Two fully independent gates offer a range of measurement options for signal height or distance using peak triggering.
    The echo-to-echo mode allows accurate gate positioning for signals which are extremely close together.
    Gate Start: Variable over entire displayed range
    Gate Width: Variable from Gate Start to end of displayed range
    Gate Height: Variable from 0 to 99% Full Screen Height
    Alarms: Threshold positive/ negative
    Memory :
    Memory of 100 channel files to store calibration set-ups
    Memory of 1000 wave files to store A-Scan patterns and instrument settings.
    All the files can be stored, recalled and cleared.
    Functions :
    Semiautomatic two point calibration: Automated calibration of transducer
    zero offset and/ or material velocity
    Flaw Locating Live display Sound-path, Projection ( surface distance) ,
    Depth, Amplitude,
    Flaw sizing: Automatic flaw sizing using AVG/ AVG or DAC, speeds reporting of defect acceptance or rejection.
    Digital Readout and Trig. Function: Thickness/ Depth can be displayed in
    digital readout when using a normal probe and Peam path, Surface
    Distance and Depth are directly displayed when angle probe is in use.
    Both the DAC and the AVG method of amplitude evaluation are available.
    Curved Surface Correction feature
    Crack Height Measure function
    Weld figure feature
    Magnify gate spreading of the gate range over the entire screen width
    Video Recording and play
    Auto-gain function
    Envelope: Simultaneous display of live A-scan at 60 Hz update rate and
    envelope of A-scan display
    Peak Hold: Compare frozen peak waveforms to live A-Scans to easily
    interpret test results.
    A Scan Freeze Display freeze holds waveform and sound path data
    B Scan display feature
    Real Time Clock
    The instrument clock keeps running tracking the time.
    Communication
    High speed USB2.0 port.
    The optional DataPro software helps manage and format stored inspection data for high-speed transfer to the PC. Data can be printed or easily copied and pasted into word processing files and spreadsheets for further reporting needs. New features include live screen capture mode and database tracking.
    Battery
    Internal rechargeable Li-ion battery pack rated 7.2V at 8800 mAh
    8 hours nominal operating time depending on display brightness
    8-10 hours typical recharge time
    Knob
    Operating adjustments are easily and quickly made using the rotary knob.
    Specifications
    Range: 0 to 6000 mm, at steel velocity
    Material Velocity: 1000 to 9999m/ s
    Display Delay: -20 to 3400 µ s
    Probe Delay/ Zero Offset : 0 to 99.99µ s
    Sensitivity: 110 dB max in selectable resolution 0.1, 1.0, 2.0, 6.0 dB and
    locked.
    Test Modes: Pulse echo, dual element and thru-transmission
    Pulse Repetition Frequency ranges from 10 Hz to 1000 Hz
    Pulse Energy: Low, Medium and High spike pulse.
    Damping: 100, 200, 400 ohms
    Bandwidth ( amplifier bandpass ) : 0.5 to 10 MHz
    Gate Monitors: Two independent gates controllable over entire sweep range
    Rectification: Positive halfwave, negative halfwave, fullwave, RF
    System Linearity: Horizontal: + / -0.2% FSW, Vertical: 0.25% FSH, Amplifier
    Accuracy + / -1 dB.
    Reject ( suppression) : 0 to 80% full screen height
    Units: Inch or millimeter
    Transducer Connections: BNC or LEMO
    Power Requirements: AC Mains 100-240 VAC, 50-60 Hz
    Dimensions: 263HÃ 170WÃ 61D mm
    Operating Temperature: -10 to 50
    Storage Temperature: -30 to 50



You have [3] new inquiries.
Go to Member Menu

Home - Trade List - Product List - Inquiry List - Cooperation List - Company List