Reference Double, Ag/ AgCl Junction/ Flow Rate Ceramic, single Electrolyte Gel Max Pressure 2 bar Range 0 to 13 pH; 0 to 80Â ° C ( 68 to 104Â ° F) Tip Shape Spheric ( dia: ....
pH Range -2.00 to 16.00 pH pH Resolution 0.01 pH pH Accuracy  ± 0.02 pH pH Calibration automatic, at one or two points with two sets of standard buffers ( pH 4.01 / 7.01 / 10.01 or pH 4.01....
Range 0.0 to 99.9 ppm as NHâ € ž z Resolution 0.1 ppm Accuracy @ 25 ° C/ 77 ° F  ± 1.0 ppm  ± 5% of reading Light Source LED @ 470 nm Light Detector silicon photocell Method adaptation....
Range 0.00 to 2.50 ppm Resolution 0.01 ppm Accuracy @ 25 ° C/ 77 ° F  ± 0.03 ppm  ± 3% of reading Light Source LED @ 525 nm Light Detector silicon photocell Method adaptation of the....
Range 0 to 300 ppm Resolution 1 ppm Accuracy @ 25Â ° C/ 77Â ° F Â ± 5 ppm ( mg/ L) Â ± 5% of reading Light Source LED @ 610 nm Light Detector silicon photocell Method colorimetric method....
Method Titration Range 0.0-40.0 g/ kg Smallest Increment 0.4 g/ kg Chemical Method Mercuric nitrate Number of Tests approx 110 Weight 460 g
Range ( pH) -2.00 to 16.00 pH Range ( Temperature) -5.0 to 105.0Â ° C / 23.0 to 221.0Â ° F Resolution ( pH) 0.01 pH Resolution ( Temperature) 0.1Â ° C / 0.1Â ° F Accuracy ( pH) Â ± 0.02 pH Accuracy ( ....
 ½ " NPT external thread for in-line installation pH electrode with exclusive PTFE non-clogging membrane Double-junction technology PVDF body In order to reduce normal contamination coming from ....
Range ( Â ° C) -50.0 to 150.0Â ° C Range ( Â ° F) -58.0 to 302.0Â ° F Resolution ( Â ° C) 0.1Â ° C Resolution ( Â ° F) 0.1Â ° F Accuracy ( Â ° C) Â ± 0.3Â ° C ( -20 to 90Â ° C) , Â ± 0.5Â ° C ( ....
Range -50.0 to 150.0 ° C Resolution 0.1 ° C Accuracy  ± 0.3 ° C ( -20 to 90 ° C)  ± 0.5 ° C ( outside) Probe fixed stainless steel 105 x dia 3 mm ( 4.1 x dia 0.1" ) ( penetration) ....
Method Colorimetric Range 0-5 mg/ L Smallest Increment 1 mg/ L Chemical Method Phenanthroline Number of Tests 50 Weight 142.5 g
Method Titration Range 0.0-30.0 mg/ L 0-300 mg/ L Smallest Increment 0.3 mg/ L 3 mg/ L Chemical Method EDTA Number of Tests 100 Weight 460 g
Conductivity Range 0 to 3999  µ S/ cm Conductivity Resolution 1  µ S/ cm Conductivity Accuracy  ± 2% F.S. TDS Range 0 to 2000 ppm ( mg/ L) TDS Resolution 1 ppm ( mg/ L) TDS Accuracy ....
Range pH -2.00 to 16.00 pH mV Â ± 399.9 mV; Â ± 2000 mV Temperature -20 to 120.0Â ° C Resolution pH 0.01 pH mV 0.1 mV; 1 mV Temperature 0.1 Â ° C Accuracy pH Â ± 0.01 pH mV Â ± 0.2 mV ( Â ± 399.9 mV) ....
Range pH -2.0 to 16.0 pH Range Temperature -5.0 to 60.0 ° C / 23.0 to 140.0 ° F Resolution pH 0.1 pH Resolution Temperature 0.1 ° C / 0.1 ° F Accuracy pH  ± 0.1 pH Accuracy Temperature  ± 0.5 ° ....