Specification
Volumetric Infusion Pump

Faster, Easier, and Clearer

1. Numerical keypad - Easy and fast way to setup.
2. Various displays - FND displays numerical data clearly and Color LCD displays detail information.
3. User friendly - Simple setup process makes user feels comfortable and variety display gives complete information.

Features and Specifications
• Flow rate range : 1~ 1000ml
• Delivery Volume : 1~ 9999ml
• Total infused volume : 1~ 9999ml ( Volume to be infused)
• Accuracy with approved IV Set : Within ± 5%
• Infusion principle : Linear Peristaltic Finger
• Alarms ( Audio & Visual) : Air in line, Occlusion, Flow error( Free Flow) , Standby K.V.O.( Infusion Completion) , Door open, Low battery, Device malfunction
• Special function : Keypad lock, Retain memory, Remaining time, Alarm repeat, Open system, K.V.O., Purge, Bolus, Occ. level, History call-back, Dosage mode( Option) ,
• Nurse call( Option) , Profile( Option) , Central system( Option)
• Weight : Approximately 3.5KG ( without rechargeable battery 3KG)
• Dimension : 100 X 190 X 250 ( mm)
• Power consumption : 40VA
• Power requirements : AC110/ 230V, 50/ 60Hz or DC9.6V, DC12V/ 24V, 2A
• Battery type : Ni-Cd rechargeable battery
• Battery operating time : 4hours ( at 125ml/ h)
• Battery recharging time : More than 6hours
• Operating condition : 10-40  , 30-85% RH ( no condensation)
• Storage condition : -10-40  , 10-95% RH ( no condensation)

Standard Features :
1. Self-testing - Every time the unit is turned on, self testing is executed.
2. K.V.O.( Keep Vein Open) - When the delivery volume has been reached, flow rate turns into K.V.O. rate ( adjustable from 1ml/ h to 10ml/ h) automatically.
3. Keypad lock function - Keypad can be locked with or without password.
4. Infusion setup - Flow rate/ Delivery volume/ Infusing time.
5. Retain memory - Last setting value will be saved.
6. Remaining time display.
7. Alarm repeat function.
8. Open system - Up to 10 IV set brands can be calibrated in single unit.
9. Buzzer level - 3steps.
10. Occlusion level - 9 steps ( 4.5 ~ 14.5 psi) .
11. Purge rate - Adjustable ( 1 ~ 1000 mL/ hr) .
12. Bolus rate - ON/ OFF, Adjustable ( 1 ~ 1000 mL/ hr, 1 ~ 9999mL)
13. History call back - Call back last 10 infusion data.

Optionals :
14. Dosage mode ( Body weight mode) - Automatically calculate and set the proper flow rate when the dose rate, body weight, drug mass and solution volume are entered.
15. Drop sensor - External.
16. Nurse call - Each unit can be connected with nurse call system ( DC 24V, 0.5A) .
17. Profile function - Program infusion condition( flow rate, delivery volume, delivery time) differently for each hour, up to 24hours.
18. Central system - Connect with main PC for monitoring.