    Megger LTW315, LTW325 and LTW335 2 wire non-tripping loop testers

    Price:
    Hub :021- 32375508
    Quantity Order:
    Origin:
    United States

    Specification :

    Specification
    General Specification
    Only values with tolerances or limits are guaranteed data. Values
    without tolerances are for information only.
    Accuracy
    All accuracy statements are based on:
    Ambient temperature: 23º ± 2º C
    Nominal source voltage: 230 V a.c ± 1%
    Voltage measurement
    ( ac only) 50V to 440 V
    Accuracy: ± 2% ± 1V
    Frequency measurement
    Range: 25Hz to 99.99Hz
    Accuracy: ± 0.1Hz
    A warning will be shown if applied voltage exceeds 440 V.
    Damage will occur if applied voltage exceeds 600 Ã rms.
    Loop testing
    Accuracy
    + / -5% + / -0.03 ohms @ 230 V a.c.
    + / -10% + / -0.03 ohms @ 100 V a.c. and 300 V a.c. ( LTW325 &
    LTW335)
    + / -10% + / -0.03 ohms @ 100 V a.c. and 280V ( LTW315)
    + / -10% + / -0.02 ohms ( LTW425)
    + / -15% + / -0.03 ohms @ 50 V a.c. ( LTW325 & LTW335)
    + / -15% + / - 0.03 ohms @ 50 V a.c. ( LTW425)
    NO-TRIP Loop and High current Loop test
    Source voltage:
    LTW315 100V to 280V ( 50Hz)
    LTW325, 335 & 425 50V to 440V ( 50Hz)
    Display range: 0.01 ½ to 2000 ½
    Accuracy: ± 5% ± 0.03 ½
    Nominal test current:
    No-Trip loop test 15 mA ( at nominal 230 V a.c supply)
    High current loop test 4 A ( at nominal 230 V a.c supply)
    EN61557
    Operational range: 0.30 ½ to 1000 ½
    High resolution loop test ( LTW425 only)
    Source voltage: 50 V to 440 V ( 50Hz)
    Display range: 0.001 ½ to 2000 ½
    Accuracy: ± 5% ± 0.01 ½
    Nominal test current: 4 A at nominal 230 V supply
    EN61557
    Operational range: 0.30 ½ to 1000 ½
    Prospective Fault Current ( PFC)
    Prospective fault current = Measured Source Voltage / Loop r
    esistance
    Maximum range: No trip mode: 20 KA
    High current mode: 20 KA
    Hi resolution mode: 40 KA
    Accuracy is derived from loop test and voltage measurement.
    Environmental
    Temperature and humidity
    Operating Range: -10° C to + 50° C
    Operating Humidity: 90% R.H. non-condensing at
    + 40° C max.
    Storage Range: -25° C to + 70° C
    Maximum altitude: 2000m to full safety specification
    Dust and water ingress: IP54
    Safety
    IEC61010
    Designed to IEC61010-1
    Designed for 300 volts to Earth Category IV, with Phase to Phase
    voltages to 440 Volts.
    Fuse protected to 600 volts rms ac.
    EN61557
    Complies with the following parts of EN61557, Electrical safety in
    low voltage systems up to 1000V ac and 1500V dc- Equipment for
    testing, measuring or monitoring of protective measures:
    Part1-General Requirements
    Part3-Loop resistance
    E.M.C
    In accordance with IEC61326-1
    Power supply
    Battery: 8 x 1, 5 V cells IEC LR6 type ( AA alkaline) .
    Rechargeable: 8 x 1.2VNiCd or NiMH cells
    Battery life: 2000 consecutive tests