Welcome to
WIJAYAMAS TEKNINDO CV

Free Member
WIJAYAMAS TEKNINDO CV
Indonesia
  • Products Catalog

    Megger RCDT300 RCD testers for electricians

    Megger RCDT300 RCD testers for electricians

    Price:
    Hub :021- 32375508
    Quantity Order:
    Origin:
    United States

    Specification :

    SPECIFICATIONS
    RCD Test Ranges ( to EN61557-6)
    Supply voltage
    Supply: RCDT310 100 V - 280 V 45Hz to 65 Hz
    RCDT320 50 V - 280 V 45Hz to 65 Hz
    RCDT330 50 V - 280 V 45 Hz to 65 Hz
    Minimum voltage 71 V for 300 mA RCDs, 100 V for
    500 mA RCDs and 205 V for 1000 mA RCDs
    Test Current Accuracy:
    No Trip Test: ( 1/ 2I) – 8% to – 2%
    Trip Test: ( I, 5I) + 2% to + 8%
    Trip Time: ± 1% ± 1ms
    Voltage measurement
    ( All Models)
    Range ac: 0V - 300V 25Hz to 450Hz
    Accuracy: ± 2% ± 2 digits
    Frequency measurement
    ( RCDT320/ 330)
    Range: 25Hz to 450Hz
    Accuracy: 25.0Hz to 199.9Hz ± 0.1Hz
    200Hz to 450Hz ± 1Hz
    Fault ( Touch) Voltage
    Displayed range: 0 V to 50 V
    Error: + 5% / + 15% ± 0.5 V
    Programmable RCD step Increments
    10 mA to 50 mA - 1 mA steps
    50 mA to 500 mA - 5 mA steps
    500 mA to 1000 mA - 10 mA steps
    Test result storage ( 1000 results)
    Job Number 256 locations
    Distribution Board no. 99 locations
    Circuits 99 locations
    Phases P1, P2, P3
    Last recorded result may be recalled to the display. All data can
    be downloaded to a PC using Download Manager ( supplied) or
    Megger Powersuite Professional Windows software
    Temperature and humidity
    Operating Range: -5° C to + 40° C
    Operating Humidity: 93% R.H. at + 40° C max.
    Storage Range: -25° C to + 70° C
    Maximum altitude: 2000m
    Environmental Protection: IP54
    Communications
    USB interface
    Safety
    Meets the requirements of IEC61010-1 Cat III 300V phase to
    earth.
    IEC61557
    Complies with the following parts of EN61557, Electrical safety
    in low voltage systems up to 1000 V ac and 1500 V dc-
    Equipment for testing, measuring or monitoring of protective
    measures:
    Part1-General Requirements
    Part4-Residual current devices
    Power supply
    Batteries: 8 x 1, 5 V cells IEC LR6 type ( AA alkaline) .
    Rechargeable: 8 x 1.2 V NiCd or NiMH cells.
    Battery Life: 2000 consecutive tests
    Weight
    All units 980gms
    Dimensions
    All units 203 x 148 x 78 mm
    E.M.C.
    In accordance with IEC61326-1