  • Sanwa Digital Multimeter CD731a,

    Sanwa Digital....

    Hub 021 - 32375508

    CD731a, New standard multimeter

    # 3-3/ 4 digits 4000 count
    # Easy to read large LCD
    # Safety cap on current terminal
    # Data hold, Range hold
    # Continuity check, Diode test
    ....

  • MDP Series Distribution Profiler

    MDP Series....

    Hub :021- 32375508

    SPECIFICATIONS
    All specifications at 25Â ° C unless otherwise specified
    Conductor Size
    0.2 in. to 1.2 in. ( .5 cm to 3.0 cm) cable outside diameter
    Current Range
    10 to 1000....

  • TTR300 series Three-Phase Transformer Turns Ratio Test Set

    TTR300 series Three....

    Hub :021- 32375508

    SPECIFICATIONSInput Power
    120/ 230 V ac  ± 10% , single phase, 50/ 60  ± 2 Hz 100 VA
    Battery Operation ( Optional)
    Inverter 12 V dc to 120 V/ 230 V ac for operation from....

  • MTO210 Transformer Ohmmeter

    MTO210 Transformer....

    Hub :021- 32375508

    sPeCIFICATIOns
    Input
    120/ 240 V, 50/ 60 Hz, 720 VA
    Output
    User Selectable Current Ranges: up to 10 mA
    up to 100 mA
    up to 1 A
    up to 10 A
    Open-Circuit Test Voltage: up to 40....

  • MCT1600B Automatic Current Transformer Saturation,  Ratio and Polarity Test Set

    MCT1600B Automatic....

    Hub :021- 32375508

    Specifications
    Input
    100 to 265 V, 1Ã ¸ , 50 or 60 Hz, 15 A max.
    Output
    Continuously variable in four ranges:
    0 to 40 V at 2.0 A max ( 5 minute on 15 minute off)
    0 to 40 V....

  • OTS60SX Semi Automatic Oil Test Set

    OTS60SX Semi....

    Hub :021- 32375508

    SPECIFICATIONS
    High Voltage Output
    Voltage:
    0 - 60 kV
    Test Frequency:
    61, 8 Hz
    Transformer rating:
    500 VA
    Output disconnection
    Within 1 ms of detection of
    breakdown
    ....

  • Megger MIT480 series Telecoms insulation and continuity testers

    Megger MIT480 series....

    Hub :021- 32375508

    SPECIFICATION
    All quoted accuracies are at + 20Â ° C.
    Insulation
    Nominal test voltages
    MIT480 50 V, 100 V
    MIT481, 485 50 V, 100 V, 250 V, 500 V, 1000 V
    Insulation resistance....

  • Megger RCDT300 RCD testers for electricians

    Megger RCDT300 RCD....

    Hub :021- 32375508

    SPECIFICATIONS
    RCD Test Ranges ( to EN61557-6)
    Supply voltage
    Supply: RCDT310 100 V - 280 V 45Hz to 65 Hz
    RCDT320 50 V - 280 V 45Hz to 65 Hz
    RCDT330 50 V - 280 V 45 Hz to 65....

  • SITS-120 Secondary Injection Test Set

    SITS-120 Secondary....

    Hub :021- 32375508

    SPECIFICATIONS
    Input Power
    120 or 240 Vac ( specify one) Â ± 10% , 50/ 60 Hz
    Outputs
    Two indenpendently controlled adjustable outputs are available
    from the test set, one ac....

  • MS-2A Circuit Breaker and Overcurrent Relay Test Set

    MS-2A Circuit....

    Hub :021- 32375508

    SPECIFICATIONS
    Input
    Input Voltage ( specify one) : 120 V OR 240 V, 50/ 60 Hz, 1f
    Output
    Output Ranges: The output is continuously adjustable in four
    ranges to accommodate a....

  • CB-832 Circuit Breaker and Overload Relay Test Set

    CB-832 Circuit....

    Hub :021- 32375508

    SPECIFICATIONS
    Input ( specify one)
    120 V OR 240 V, 50/ 60 Hz, 1f, 20A
    Output
    Output Ranges: Continuously adjustable in three ranges to meet
    a variety of test circuit....

  • PA9Plus Power Analyser

    PA9Plus Power....

    Hub :021- 32375508

    SPECIFICATIONS
    Specifications are at 25Â ° C ( 77Â ° F) .
    Applicable Measurement Standards
    EN50160, IEEE1159, IEEE519, IEC61000-4-15, IEC 61000-4-30
    Voltage ( 4 Differential....

  • MEGGER PAT32 Portable Appliance Tester

    MEGGER PAT32....

    Hub :021- 32375508

    SPECIFICATIONS
    Tests Available
    ( 1) Circuit test
    ( 2) Fuse check
    ( 3) Earth Continuity test
    ( 4) 10 A Earth Bond test
    ( 5) 25 A Earth Bond test
    ( 6) Insulation test
    ( 7) ....

  • Megger AVO300 series Digital multimeters

    Megger AVO300 series....

    Hub :021- 32375508

    SPECIFICATIONSTechnical: Insulation: Class2, Double insulation.Overvoltage category: ( AVO300/ 310)
    CATIII 600 V / CATII 1000 V
    Display
    AVO300: 4000 counts LCD display, 25.4....

  • Megger DLRO200 Digital Low Resistance Ohmmeter

    Megger DLRO200....

    Hub :021- 32375508

    SPECIFICATIONS
    Measurement:
    Range: 0.1  ¼  ½ to 999.9 m ½
    ( Subject to supply voltage and leads used)
    Accuracy:
    Voltage  ± 0.5%  ± 0.1 mV
    Current  ± 0.5%  ± 0.1 A
    ....

  • Megger DLRO10X Digital Low Resistance Ohmmeters

    Megger DLRO10X....

    Hub :021- 32375508

    SPESIFICATION :
    Full Scale
    1.9999 m ½
    19.999 m ½
    199.99 m ½
    1.9999 Â ½
    19.999 Â ½
    199.99 Â ½
    1999.9 Â ½
    Resolution
    0.1 Â ¼ Â ½
    1 Â ¼ Â ½
    10 Â ¼ Â ½
    100 Â ¼ Â ½
    1 m ½ ....

  • Megger LTW315,  LTW325 and LTW335 2 wire non-tripping loop testers

    Megger LTW315, ....

    Hub :021- 32375508

    Specification
    General Specification
    Only values with tolerances or limits are guaranteed data. Values
    without tolerances are for information only.
    Accuracy
    All accuracy....

  • Megger LT300 High current loop tester

    Megger LT300 High....

    Hub 021 - 32375508

    SPECIFICATION
    Voltage measurement range
    Voltage range: 0 V to 550 V ( 400 V @ 16 Hz)
    Accuracy: Â ± 5% Â ± 2 V
    Loop test operating frequencies
    16 Hz 15 Hz to 18 Hz, 33 Hz, 29....

  • DELTA4000 Series 12 kV Insulation Diagnostic System

    DELTA4000 Series 12....

    Hub 021 - 32375508

    SPECIFICATIONSInput Power
    100-240 V Â ± 10 % , 50/ 60 Hz, 16 A max
    Output Voltage
    0 to 12 kV, continuously adjustable
    Test Frequency Range
    45-70 Hz ( 12 kV)
    15-400 Hz ( 4 kV....

  • DELTA3000 10-kV Automated Insulation Power Factor Test Set

    DELTA3000 10-kV....

    Hub 021 - 32375508

    SPECIFICATIONSInput
    120/ 230 V Â ± 10% , 1Ã † , 50/ 60 Hz, 1440 VA
    Output
    0 to 12 kV, continuously adjustable, 200 mA continuous;
    310 mA maximum for up to 5 minutes.
    The power....

  • MEGGER MJ15 and BM15 5 kV Insulation Testers

    MEGGER MJ15 and BM15....

    Hub 021 - 32375508

    SPECIFICATION
    Insulation Range:
    100 k © to 20 G © ( also 0  © and  )
    Test Voltages ( d.c.)
    500 V, 1000 V, 2500 V & 5000 V
    Test Voltage Accuracy
    Â ± 5% of nominal test....

  • Megger S1-552/ 2 5 kV high current insulation resistance tester

    Megger S1-552/ 2 5....

    Hub 021 - 32375508

    SPECIFICATIONSVoltage input range
    85-265 V rms, 50/ 60Hz, 60 VA
    S1-552/ 2 battery life
    Typical capacity is 6 hours continuous testing at 5 kV with a 100 MÂ © load
    S1-1052/ 2....

  • Megger MIT520/ 2 Diagnostic insulation resistance tester 5kV

    Megger MIT520/ 2....

    Hub 021 - 32375508

    SPECIFICATIONVoltage input range
    85-265 V rms, 50/ 60 Hz, 60 VA
    MIT520/ 2 battery life
    Typical capacity is 6 hours continuous testing at 5 kV with a 100 MÂ © load
    MIT1020/ 2....

  • Megger MIT40X Special applications insulation and continuity testers

    Megger MIT40X....

    Hub 021 - 32375508

    SPECIFICATION
    Insulation
    Nominal test voltages
    MIT40X 10 V to 100 V variable ( 1 V increments)
    Insulation resistance range ( at maximum test voltage)
    MIT40X 20 GÂ ½
    Range....

  • DET14C and DET24C Clamp-on earth resistance tester

    DET14C and DET24C....

    Hub 021 - 32375508

    Resistance measurements
    Ground resistance range :
    0.05 Â © to 0.99 Â ©
    1.00 Â © to 9.99 Â ©
    10.0 Â © to 99.9 Â ©
    100.0 Â © to 199.9 Â ©
    200 Â © to 400 Â ©
    400 Â © to 600 Â ©
    ....

  • MEGGER PFL40A-2000 Portable cable fault location and high voltage test solution with high energy surge

    MEGGER PFL40A-2000....

    Hub :021- 32375508

    SPECIFICATIONS
    Testing
    Output: 0 â € “ 20 kV d.c. Imax 25 mA ( negative to earth)
    Resolution: 1 mA
    Trip: Adjustable current trip ( max 50 mA)
    Metering: Analogue and digital....

  • Megger BITE3 Battery Impedance Test Equipment

    Megger BITE3 Battery....

    Hub :021- 32375508

    SPECIFICATIONS
    BITE3 Instrument
    Impedance Range and Resolution
    0.05 to 1.000 m © 1  ¼  © resolution
    1 to 10.00 m © 10  ¼  © resolution
    10 to 100.0 m © 0.1 m © resolution
    ....

  • BITE® 2 and BITE2P Battery Impedance Test Equipment

    BITEÂ ® 2 and BITE2P....

    Hub :021- 32375508

    SPECIFICATIONS
    Application
    The BITE2 and BITE2P test lead-acid and nickel-cadmium cells up
    to 7000 Ah.
    Maximum Total Voltage at Current Source Leads
    275 V dc ( larger battery....

  • MPRT( Megger Protective Relay Test System) Model 8430

    MPRT( Megger....

    Hub :021- 32375508

    SPESIFICATION:
    Model 8430
    Per phase:
    Output Current Power Max V
    4 Amperes 200 VA 50.0 Vrms
    7.5 Amperes 200 VA 26.7 Vrms
    15 Amperes 200 VA 13.4 Vrms
    30 Amperes 200 VA 6.67....

  • MGTR ( Megger GPS Timing Reference)

    MGTR ( Megger GPS....

    Hub :021- 32375508

    SPECIFICATIONS
    Input Power
    AC/ DC Adapter
    90 to 265 VAC, 47-63 Hz to 24 VDC, 400mA, with 4-plug kit
    Disciplined Oscillator
    High performance ovenized crystal control ( OCXO)
    ....

  • Megger DCM 310 and DCM 320

    Megger DCM 310 and....

    Hub :021- 32375508

    SPECIFICATION
    All accuracies specified at 23Â º C Â ± 5Â º 85% RH
    DCM310
    AC current
    ( 50 - 60 Hz)
    Range : 0-19.99A to 400A
    Accuracy : Â ± 3% Â ± 0.05 A, Â ± 2% Â ± 0.5 A, Â ± 2% Â ± ....

  • MEGGER DCM330 Fork Multimeter

    MEGGER DCM330 Fork....

    Hub :021- 32375508

    SPECIFICATION
    ( accuracies specified at 23Â º C)
    AC current
    Frequency 50 - 60 Hz
    Range 0 - 200.0 A
    Accuracy
    Â ± 3% Â ± 3 digits
    Average sensing, RMS indicating
    Overload....

  • DCM340 Digital Clampmeter

    DCM340 Digital....

    Hub :021- 32375508

    SPECIFICATION
    Base specifications only. For detailed specification, refer to User
    Guide
    All accuracies specified at 23Â ° C Â ± 5Â °

  • Fluke 1750 Three-Phase Power Recorder

    Fluke 1750 Three....

    Hub 021 - 32375508

    Technical Specifications
    Power quality measurement standards
    Conformance IEC 61999-1-4 Class 1, IEC 61000-4-30 Class A or B depending on measurement function, IEEE519, ....

  • Fluke 60 Series Handheld Infrared Thermometers Specifications

    Fluke 60 Series....

    Hub 021 - 32375508

    Specifications
    Backlit display for use in poorly lit areas
    Fluke 61 Yes
    Fluke 63 Yes
    Fluke 66 Yes
    Fluke 68 Yes
    Holds temperature readings
    Fluke 61 Yes
    Fluke 63 ....

  • Fluke ScopeMeter® 190 Series

    Fluke ScopeMeter ® ....

    Hub 021 - 32375508

    Specifications
    Bandwidth
    Fluke 199C: 200 MHz
    Fluke 196C: 100 MHz
    Fluke 192C: 60 MHz
    Real-time sample rate
    Fluke 199C: 2.5 GS/ s
    Fluke 196C: 1 GS/ s
    Fluke 192C: ....

  • Fluke ScopeMeter® 120 Series

    Fluke ScopeMeter ® ....

    Hub 021 - 32375508

    Specifications
    Oscilloscope Bandwidth
    Fluke 125: 40 MHz
    Fluke 124: 40 MHz
    Fluke 123: 20 MHz
    Dual input True RMS Meter
    Vdc, Vac, Vac+ Vdc, Ohms, Continuity , Diode-test....

  • Fluke 922 Airflow Meter

    Fluke 922 Airflow....

    Hub 021 - 32375508

    Technical Specifications
    Air Pressure
    Range/ Resolution/ Accuracy  ± 4000 Pascals / 1 Pascal /  ± 1 % + 1 Pascal
    Â ± 16 in H2O / 0.001 in H2O / Â ± 1 % + 0.01 in H2O
    Â ± 400 mm....

  • Fluke 971 Temperature Humidity Meter

    Fluke 971....

    Hub 021 - 32375508

    Specifications
    Temperature
    -20Â ° C to 60Â ° C ( -4Â ° F to 140Â ° F)
    Temperature accuracy
    0Â ° C to 45Â ° C ( Â ± 0.5Â ° C)
    -20Â ° C to 0Â ° C & 45Â ° C to 60Â ° C ( Â ± 1.0Â ° C)
    32Â ....

  • Fluke 975 AirMeter

    Fluke 975 AirMeter

    Hub 021 - 32375508

    Measured specifications
    Temperature
    Range: -20 Â ° C to 50 Â ° C ( -5 Â ° F to 122 Â ° F)
    Display resolution: 0.1 Â ° C ( 0.1 Â ° F)
    Accuracy: Â ± 0.9 Â ° C/ Â ± 1.62Â ° F from....

  • Fluke 50 Series II Thermometers

    Fluke 50 Series II....

    Hub 021 - 32375508

    Specifications
    Temperature accuracy
    Above -100 Â ° C: J, K, T, E, and N-type: Â ± [ 0.05% + 0.3Â ° C] *
    R and S-type: Â ± [ 0.05% + 0.4Â ° C] *

    Below -100 Â ° C: J, K, E, ....

  • Fluke 570 Precision Infrared Thermometers

    Fluke 570 Precision....

    Hub 021 - 32375508

    Technical Specifications
    Temperature range
    -30 to 900Â ° C
    ( -25 to 1600 Â ° F)
    Display Resolution
    0.1Â ° C of reading up to 900Â ° C
    0.2Â ° F of reading up to 999.8Â ° F
    D: S ( ....

  • Fluke Ti25 Thermal Imager

    Fluke Ti25 Thermal....

    Hub 021 - 32375508

    Detailed specifications
    Temperature
    Temperature measurement range ( not calibrated below -10 Â ° C) -20 Â ° C to + 350 Â ° C ( two ranges)
    Accuracy  ± 2  ° C or 2 % ( ....

  • Fluke 789 ProcessMeterâ„¢

    Fluke 789....

    Hub 021 - 32375508

    Specifications
    Current Measurement
    Range: 0-1 A AC or DC
    Resolution: 1 mA
    Accuracy: 0.2% + 2 LSD ( DC)

    Range: 0-30 mA
    Resolution: 0.001 mA
    Accuracy: 0.05% + ....

  • Fluke 705 Loop Calibrator

    Fluke 705 Loop....

    Hub 021 - 32375508

    Specifications
    Current Measurement
    Range: 0 to 24 mA
    Resolution: 0.001 mA
    Accuracy: 0.02% Rdg + 2 LSD
    Current Sourcing
    Range: 0 to 20 mA or 4 to 20 mA
    Accuracy: 0....

  • Fluke 712 RTD Calibrator

    Fluke 712 RTD....

    Hub 021 - 32375508

    Functional specifications
    Measure / simulate RTD
    Range: 0 Â © to 3200 Â ©
    Resolution: 0.1 Â ©
    Accuracy: 0.025% + .01 to 0.55%

    Specifications
    Display
    Clear 5 digit....

  • Fluke 725 Multifunction Process Calibator

    Fluke 725....

    Hub 021 - 32375508

    Specifications
    Ramp Functions
    Source functions: Voltage, current, resistance, frequency, temperature
    Ramps Slow ramp, Fast ramp, 25% step-ramp
    Loop Power Function
    Voltage: ....

  • Fluke 1587/ 1577 Insulation Multimeters

    Fluke 1587/ 1577....

    Hub 021 - 32375508

    Specifications
    Voltage DC
    Maximum Voltage: 1000 V
    Accuracy:
    1577: Â ± ( 0.2% + 2)
    1587: Â ± ( 0.09% + 2)