Welcome to
Chongqing Xinnuo Kang Medical Equipment Co., Ltd.

Free Member
Chongqing Xinnuo Kang Medical Equipment Co.,  Ltd.
Chongqing Xinnuo Kang Medical Equipment Co., Ltd.
China
  • Products Catalog

    JX-400( T) High-Frequency Jet Ventilator

    JX-400( T) High-Frequency Jet Ventilator

    Price:
    Affordable
    Quantity Order:
    Origin:
    China
    Payment Method:
    Telegraphic Transfer (T/T)
    Pack. & Delivery:
    UNIT

    Specification :

    Feature:

    1. HFJV( High-frequency jet ventilation) with pressure support, which can supply a higher inspiratory pressure so that the patients can aspirate enough oxygen easily.
    2. Opening airway. The ventilation can be made with high frequency and little tidal volume and low airway pressure, which is beneficial to increase the blood oxygen concentration .
    3. Ventilation mode through nasal vestibule noninvasive which can avoid from tracheotomy and endotracheal tube so as to reduce patient' s pain and the effectiveness of oxygen feeding is very good, The patient can talk or eat when ventilating.
    4. Continuous positive airway pressure with adjustable oxygen concentration and attached effective humidifier can make the feature of CPAP better.
    5. The multi-functional humidifier adaptor can be connected with any type of humidifier by trachea intubation with national or international standard.
    6. The pressure humidifier adaptor has gas volume control switch and the sensitive alarm with sound and light for power failture or no gas supplying

    Technique Parameter:

    1. Frequency: 10~ 150 breaths/ min
    2. I/ E ratio: 1 : 1~ 1 : 4 and inverse ratio
    3. Humidifying rate : No less than 15ml/ h
    4. Process Ventilation: T= 10min, I/ E= 1: 1.5
    ProI: T1( 150bpm) : T2( 15bpm) = 7: 3
    ProII: T2 ( 15 bpm) : T1( 150 bpm) = 7: 3
    5. SIGH: 6breaths/ min
    6. Alarm for upper-limitation of airway pressure: With 0.5Kpa, 1.0Kpa, 2.0Kpa three gears, alarm with sound and light when it exceeds the setting value. 7. Alarm: Alarm with light and sound for power failure and alarm will last for 6 seconds when no oxygen.
    7. CPAP: 0.1Kpa~ 0.8kPa
    8. PEEP: 0.1Kpa~ 0.5kPa
    9. Maximum Output Oxygen Concentration : 85%
    10. Synchronous sensitivity : -2~ 0.1KPa
    11. Ventilation Modes: HFJV( High Frequency Jet Ventilation) ; CPAP( Continuous positive airway pressure) ; ProI and ProII ventilation; HFJV+ PEEP , HFJV+ SIGH and Manual ventilation