    Specification :

    Specification :
    EC Range : 0.00 to 29.99 µ S/ cm; 30.0 to 299.9 µ S/ cm; 300 to 2999 µ S/ cm; 3.00 to 29.99 mS/ cm; 30.0 to 200.0 mS/ cm; up to 500.0 mS/ cm actual Conductivity*
    TDS Range : 0.00 to 14.99 mg/ l ( ppm) ; 15.0 to 149.9 mg/ l ( ppm) ; 150 to 1499 mg/ l ( ppm) ; 1.5 to 14.99 g/ l ( ppt) ; 15.0 to 100.0 g/ l ( ppt) ; up to 400.0 g/ l actual TDS* ( with 0.80 factor)
    NaCl Range : 0.0 to 400.0%
    Temp Range : -20.0 to 120.0° C / -4.0 to 248.0° F

    EC Resolution : 0.01 µ S/ cm; 0.1 µ S/ cm; 1.0 µ S/ cm; 0.01 mS/ cm; 0.1 mS/ cm
    TDS Resolution : 0.01 mg/ l; 0.1 mg/ l; 1.0 mg/ l; 0.01 g/ l; 0.1 g/ l
    NaCl Resolution : 0.1%
    Temp Resolution : 0.1° C / 0.1 ° F
    EC Accuracy : ± 1% of reading ± ( 0.05 µ S/ cm ro 1 digit)
    TDS Accuracy : ± 1% of reading ± ( 0.03 mg/ l or 1 digit)
    NaCl Accuracy : ± 1% of reading
    Temp Accuracy : ± 0.4° C / ± 0.8° F
    EC Calibration : 1 point slope calibration with 6 memorized solutions ( 84.0 µ S/ cm, 1413 µ S/ cm, 5.00 mS/ cm, 12.88 mS/ cm, 80.0 mS/ cm, 111.8 mS/ cm)
    NaCl Calibration : 1 point, with MA9066 calibration solution
    Temp Calibration 2 points, 0 to 50° C / 32 to 12 ° F
    Temp. Compensation automatic or manual, : from -20.0 to 120.0° C / -4.0 to 248.0° F
    Temp. Coefficient : selectable from 0.00 to 6.00% / ° C ( EC and TDS only)
    Probe : MA813D/ 1 4-ring probe with built-in temperature sensor ( included)
    TDS Factor : 0.40 to 0.80 ( default value is 0.50)
    Log on Demand : up to 50 samples on each range ( EC, TDS, NaCl)

    Mi170 is supplied complete with
    • MA813D/ 1 EC/ TDS/ NaCl/ Temperature Probe
    • MA9315 Electrode Holder
    • M10030 12880 µ S/ cm calibration solution
    • M10031 1413 µ S/ cm calibration solution
    • Mi5200 Application Software
    • MA9350 RS232 connection cable with 2 meters cable
    • 12 VDC Adapter
    • Instruction manual