    Specification :
    pH Range : -2.00 to 16.00 pH; -2.000 to 16.000 pH
    mV Range : ± 699.9 mV; ± 2000 mV
    EC Range : Conductivity 0.00 to 29.99 µ S/ cm; 30.0 to 299.9 µ S/ cm; 300 to 2999 µ S/ cm; 3.00 to 29.99 mS/ cm; 30.0 to 200.0 mS/ cm; up to 500.0 mS/ cm uncompensed EC*
    TDS Range : 0.0 to 14.99 mg/ l ( ppm) ; 15.0 to 149.9 mg/ l ( ppm) ; 150 to 1499 mg/ l ( ppm) ; 1.50 to 14.99 g/ l ( ppt) ; 15.0 to 100.0 g/ l ( ppt) ; up to 400.0 g/ l actual TDS* ( with 0.80 factor)
    NaCl Range : Salinity 0.0 to 400.0%
    Temp Range : -20.0 to 120.0° C / -4.0 to 248.0° F

    pH Resolution : 0.01 pH; 0.001 pH
    mV Resolution : 0.1 mV; 1 mV
    EC Resolution : 0.01 µ S/ cm; 0.1 µ S/ cm; 1 µ S/ cm; 0.01 mS/ cm; 0.1 mS/ cm;
    TDS Resolution : 0.01 mg/ l; 0.1 mg/ l; 1.0 mg/ l; 0.01 g/ l; 0.1 g/ l
    NaCl Resolution : 0.1%
    Temp Resolution : 0.1° C / 0.1° F
    pH Accuracy : ± 0.01 pH; ± 0.002 pH
    mV Accuracy : ± 0.2 mV; ± 1 mV
    EC Accuracy : ± 1% of reading ± ( 0.05 µ S/ cm or 1 digit)
    TDS Accuracy : ± 1% of reading ± ( 0.03 ppm or 1 digit)
    NaCl Accuracy : ± 1% of reading
    Temp Accuracy : ± 0.4° C / ± 0.8° F
    Rel mV Offset : ± 2000 mV
    pH Calibration : 1, 2 or 3 points calibration, with 7 memorized buffers ( pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45)
    EC Calibration : 1 point slope calibration with 6 memorized solutions: ( 84 µ S/ cm, 1413 µ S/ cm, 5.00 mS/ cm, 12.88 µ S/ cm, 80.0 µ S/ cm, 111.8 mS/ cm)
    NaCl Calibration : 1 point, with MA9066 solution
    Temp Calibration : 2 point, at 0 and 50° C / 32 and 122° F
    Temperature Compensation : automatic or manual, from -20.0 to 120.0° C / -4.0 to 248.0° FF
    Temperature Coefficient : selectable from 0.00 to 6.00% / ° C ( EC and TDS only)
    pH Electrodes & Temp Probe : MA917B/ 1 & MA831R ( included)
    TDS Factor : 0.40 to 0.80 ( default value is 0.50)
    Log on demand : up to 50 samples on each range ( pH, mV, EC, TDS, NaCl)
    GLP : last pH, EC, NaCl calibration data
    PC Interface : RS232 / USB Opto-isolated
    Environment : 0 to 50° C / 32 to 122° F; max RH 95%
    Power supply : 12 VDC power adapter ( included)
    Dimensions : 230 x 160 x 95 mm
    Weight : 0.9 kg

    Mi180 is supplied complete with:
    • MA917B/ 1 pH Electrode
    • MA813D/ 1 EC/ TDS/ NaCl/ Temperature probe
    • MA831R Temperature Probe
    • MA9315 Electrode Holder
    • M10004 pH 4.01 Sachet Buffer Solution
    • M10007 pH 7.01 Sachet Buffer Solution
    • M10010 pH 10.01 Sachet Buffer Solution
    • M10016 Sachet Electrode Cleaning Solution
    • Mi5200 Application Software
    • MA9350 RS232 connection cable with 2 meters cable
    • Graduate Pipet, 12 VDC Adapter & Instruction manual


You have [3] new inquiries.
Go to Member Menu

Home - Trade List - Product List - Inquiry List - Cooperation List - Company List
Copyright © 2024 Indotrade.co. All Rights Reserved.