Welcome to
CV ANDALAN PRIMA SEJAHTERA
Company Contact | ||
---|---|---|
Name: | Mr. Boni Fancius Napitupulu | |
E-mail: | Send Message | |
Instant Messaging: | 081514803457 | |
Mobile Number: | ||
Phone Number: | ||
Address: | BEKASI, Jawa Barat Indonesia | |
Average User Review | There is no review for this company - Write a review | |
Registration Date: | Jun. 25, 2024 | |
Last Updated: | Mar. 17, 2015 | |
Business Nature: | Trade, Service of Industrial Supplies category | |
Want to contact this company?
| ||
Put on Company Partner | ||
Recommend to your friends | ||
Company Brief | ||
B1. Temperature B2. Flow B3. Fill Level / Limit Valvue / Level B4. Analysis B5. Humidity B6. Pressure B7. Weighing Instruments B1. Temperature The measuring and monitoring of temperature with resistance thermometers or thermocouples is the most common method to watch and control processes. Here the temperature gets a electrical unit by using the thermoelectric effect ( thermocouple) or a resistance change. This measuring value can be converted to standard signals by our transmitter for further usage. Industrial measurement and control technology Process measurement Pipeline and tank construction Furnace construction Plastics industry Food industry Surface measurements Plant and machine construction Room temperature measurement EX - applications SIL 2 - applications > Temperature probes > Temp.probes + data logger > Temp.probes + transmitter > Transmitters > Temperature monitors > Displays > Accessories B2. Flow Piston, Valve Design Piston, Inline Design Variable Area Dynamic Diaphragm Paddle Calorimetry Rotor, Inline Rotor, Inline Model Rotor, Probe Form Turbine Gearwheel Magnetic Inductive, Inline Model Magnetic Inductive - Probe Form Spindle ( Screw) Vortex Sight glass, flap, ball Diaphragm / Limiter Filtration Manifold Block B3. Fill Level / Limit Value / Level - Accessories / Options B4. Analysis pH / ORP: The measuring devices and the transducers operate with the standard pH and ORP measurement chains. The measuring devices are fitted with comprehensive monitoring functions of the measurement chains. For measuring tasks that are to be carried out over a great-er distance of 5 m to 100 m, the impedance converter pH40 is implemented. Conductivity: The conductive measurement of the conductivity of liquids for monitoring and controlling in the ongoing process is a varied measurement process in industry. In the pharmaceutical industry a high degree of hygiene and cleaning of the plants is necessary. This process is fulfilled by ultra-pure water. O2, CO, CO2: Oxygen ( O2) , carbon monoxide ( CO) and carbon dioxide ( CO2) measurements are mainly used for ambient air monitoring. CO2 and O2 are important indicators for ambient air quality and therefore important for modern climate control. The recommended CO2 limit for indoor air is 1000 ppm. Concentrations considerable above this limit causes fatigue and poor concentration. At values considerably lower than that limit there is a high energy saving potential at the climate control with optimized air change rates. B5. Humidity Humidity-Temperature-Transmitter incl. Sensor GHTU 2 x output 4..20 mA, 0..1 V or 0..10 V for humidity and temperature, LC-Display 4-digit, Supply voltage: 12..30 V DC at 4..20 mA, 0..1 V 18..30 V DC at 0..10 V 0..100 % r.h., -40..100  ° C Humidity-Transmitter Temperature measurement via Pt100, Output: 0..10 V ( 3-wire) 4..20 mA ( 2-wire) , for humidity and temperature, Supply voltage: 12..30 V DC at 4..20 mA 24 V DC at 0..10 V, Rod shape, wall- and duct mounting 0..100 % r.h., -30..+ 70  ° C B6. Pressure GHTU Humidity-Temperature-Transmitter incl. Sensor GHTU 2 x output 4..20 mA, 0..1 V or 0..10 V for humidity and temperature, LC-Display 4-digit, Supply voltage: 12..30 V DC at 4..20 mA, 0..1 V 18..30 V DC at 0..10 V 0..100 % r.h., -40..100  ° C Data sheet RF90 Humidity-Transmitter Temperature measurement via Pt100, Output: 0..10 V ( 3-wire) 4..20 mA ( 2-wire) , for humidity and temperature, Supply voltage: 12..30 V DC at 4..20 mA 24 V DC at 0..10 V, Rod shape, wall- and duct mounting 0..100 % r.h., -30..+ 70  ° C Data sheet B7. Weighing Instruments Weighing instruments / Force Precision measurement for sales and table scales Industry applications like weighing bridges, big containers, tanks and silos Wide range of applications like plate form, table scales, belt-, small container-, tank- and package weigher Connection of all standard measuring cells Large range of applications Transmitter for DIN rail mounting Panelmeter Measuring ranges from 5 kg up to 100 t Ex devices Photo Type Description Measuring input Documents DMS50 Transmitter with Profibus  ± 9999( 0) Digit, LC-Display Measuring programmable, Line compensation via sense line, max. 4 alarm outputs, Analog output, Supply voltage: 24 V DC, 115 V AC, 230 V AC, DIN rail mounting TS35 Direct connection of DMS-cells, Bridge sensitivity 0.1..5.0 mV/ V Data sheet DMS50EX Transmitter with Profibus and Ex  ± 9999( 0) Digit, LC-Display Measuring programmable, Line compensation via sense line, max. 2 alarm outputs, Analog output, Supply voltage: 24 V DC, 115 V AC, 230 V AC, DIN rail mounting TS35 Direct connection of DMS-cells, Bridge sensitivity 0.5..5.0 mV/ V Data sheet DMS9648 DMS Bridge Panelmeter  ± 9999( 0) Digit, 14, 2 mm red, Measuring programmable, Line compensation via sense line, max. 4 alarm outputs, Analog output, Supply voltage: 24 V DC, 24 V AC, 115 V AC, 230 V AC Panelmeter DIN 96x48 mm Direct connection of DMS-cells, Bridge sensitivity 0.9..6.6 mV/ V Data sheet SBB1616 DMS-Bridge Amplifier Bridge supply 2..10 V Line compensation up to 1 V Supply voltage: 24 V DC, 24 V AC, 115 V AC, 230 V AC Field case, aluminum max. 6 DMS sensors connectable Data sheet Load cells KR High Power Load-Cell Traction and force, Line compensation via sense line, Case material steel 50 kg..30 t Data sheet KS Heavy load Load-Cell Force power, Line compensation via sense line, Case material steel 50 kg..100 t Data sheet PC22 Precision Load-Cell Standard and Ex-devices, Line compensation via sense line, Case material aluminum 5 kg..40 kg Data sheet SB8 Share-Beam Load-Cell Standard and Ex-device, Line compensation via sense line, Case material SS-type 1.4548 10 kg..500 kg Data sheet ULB DMS-Load-Cell Standard and Ex-devices, Line compensation via sense line, Case material aluminum 100 kg..5000 kg Data sheet RC3 High Power Load-Cell Standard and Ex-device, Line compensation via sense line, Case material SS-type 1.4548 7.5 kg..100 t Data sheet C: " Hygienic Design " D: Laboratory Instrumentation E: Industrial Electronics F: Measurement Data Aquisition C: Process Instrumentation Hygienic Designed GHMadapt processconnection Temperature Magnetic Inductive Flow Flow Calorimetric Point Level Capacitive Point Level Conductive Level calorimetry GHMsilverline - Features Robust and water-proof housing Water-proof connections and water-proof probes, sensors or electrodes ( depending on meas. set) Data logger function Serial interface and analog output Silicone protection cover Large double display Background illumination Wide spectrum of measurands GHMsilverline - Handheld measuring devices in a set Each GHMsilverline set includes a complete measuring set containing the following components: Water-proof handheld instrument High-quality case Flash drive wiht operating software and manual USB adapter and cable with connection for analog output Manufacturer ´ s calibration at delivery Gratis manufacturer ´ s calibration after 1 year with automatic reminding from our calibration laboratory Accessories like e.g. water-proof pH electrode and buffer solutions or water-proof temperature probe ( depending on set type) E: Industrial Electronics E1 Displays / Controller E2 Transmitter E3 Isolating Converter E4 Safety and Monitoring E 5 Power Electronic E6 Calibrating and Testing F: Measurement Data Aquisition F1 Data logger / EASYBus F2 Test Bench Measurement F3 Renewable Energie | ||
|
You have [3] new inquiries. Go to Member Menu Home - Trade List - Product List - Inquiry List - Cooperation List - Company List Copyright © 2024 Indotrade.co. All Rights Reserved. |