Free Member
PT. ANDALAN BANGUN SEJAHTERA
http://indotrade.co/andalbangunsejahtera/
\"JENCO INSTRUMENT - JEKEN Ultrasonic Cleaner - MITECH Ultrasonic thickness - DAVIS Weather Station - EUTECH Instrument - SOCOREX Liquid Handling - MEMMERT - BLUE GIZMO Instrument - HACH - OHAUS Balance - VITLAB Plasticware - DURAN Glassware - KETT
Contact Information
Name:

Mrs. Pera / Krisna / Juni [Marketing]

E-mail:
Phone Number:

Phone number of Mrs. Pera / Krisna / Juni at Jakarta Pusat

Mobile Number:

Mobile number of Mrs. Pera / Krisna / Juni at Jakarta Pusat

Fax Number:

Fax number of Mrs. Pera / Krisna / Juni at Jakarta Pusat

Address:

Jl. Sumur Batu Raya No. 1 RT 001 RW 006, Kemayoran
Jakarta Pusat 10640, Jakarta
Indonesia

Average User Review

There is no review for this company

Write a review
Language :

Sell

BINDER, Drying Oven, Drying and heating chambers with forced convection
Priceinquiry
Quantity Order:
Payment MethodTelegraphic Transfer (T/T)
Quantity1 unit
Pack. & Deliveryper unit
OriginGermany
Model : FD 23
Capacity : 20 liter

A BINDER FD series drying oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous temperature distribution, quick dynamics and powerful fan, it saves valuable time.

Advantages:

* Fast, even tempering
* Wide temperature range
* Quality " Made in Germany"

Exterior dimensions
Width ( mm) 435
Height ( incl. feet) ( mm) 495
Depth ( mm) 520
Plus door handle and connection ( mm) 85
Wall clearance, rear ( mm) 100
Wall clearance, side ( mm) 100
Exhaust duct ( outer Ø mm) 52
Steam space volume ( l) 36
Number of doors ( ea.) 1

Interior dimensions
Width ( mm) 222
Height ( mm) 330
Depth ( mm) 277
Interior volume ( l) 20
Racks ( number standard/ max.) 2 / 3
Load per rack ( kg) 12
Permitted total load ( kg) 25
Weight ( empty) ( kg) 33

Temperature data
Temperature range approx. 5 ° C above ambient temperature to ( ° C) 300
Temperature variation
at 70 ° C ( ± K) 0, 8
at 150 ° C ( ± K) 2, 2
at 300 ° C ( ± K) 4, 3
Temperature fluctuation at 70 ° C ( ± K) 0, 3
Warm-up time 1)
to 70 ° C ( min.) 7
to 150 ° C ( min.) 22
to 300 ° C ( min.) 45
Recovery time after doors were open for 30 sec. 1)
at 70 ° C ( min.) 2
at 150 ° C ( min.) 4
at 300 ° C ( min.) 9

Ventilation data
Ventilation
at 70 ° C ( x/ h) 59
at 150 ° C ( x/ h) 64
at 300 ° C ( x/ h) 53

Electrical data
IP protection class acc. to EN 60529 IP 20
Voltage ( ± 10% ) 50 / 60 Hz ( V) 230
Nominal power ( kW) 0, 8
Energy consumption
at 70 ° C ( W) 145
at 150 ° C ( W) 300
at 300 ° C ( W) 720
You have [3] new inquiries. Go to Member Menu
Home - Trade List - Product List - Inquiry List - Cooperation List - Company List
Copyright © 2024 Indotrade.co. All Rights Reserved.