    Specification :

    The advanced PEN direct reading dosimeters are rugged, precision instruments. They are higher quality and have greater reliability than other dosimeters of this type. They measure and directly read, at any time, accumulated dose ( quantity of gamma and x-ray exposure) . PEN dosimeters are designed to satisfy military specifications for the RADIAC METER IM-264/ PD and ANSI N 13.5 and N322 requirements. A sturdy metal clip attaches the dosimeter to a pocket or any object to monitor total radiation exposure. They are hermetically sealed and immersion proof.
    Specifications
    Exposure Range ( gamma and x-rays)
    PEN200mR Scale increments of 10mR
    PEN500mR Scale increments of 20mR
    PEN2R increments of 100 mR
    PEN5R increments of 200mR
    PEN20R increments of 1R
    PEN2mSv increments of .1mSv
    PEN5mSv increments of .2mSv
    National Stock Numbers Available
    Energy Dependence
    ± 10% maximum change in sensitivity for x and gamma ray energies from 16 keV to 8 MeV.
    Electrical Leakage
    In the absence of radiation, the dosimeters leakage or self discharge is less than 0.5% of full scale in 24 hours at 50° C. At 20° C dosimeters will read background radiation. After gross over exposure totaling up to 2000 R the leakage is less than 5% of full scale in 48 hours at 20° C. Thereafter, the leakage will decrease to original values.
    Charging Voltage
    Dosimeters are capable of being charged to " zero" with 140 to 195 volts.
    Operational Characteristics
    A maximum change in sensitivity of ± 10% may occur under any probable combination of the following:
    A) Temperature range below -20° C ( -4° F) or above + 50° C ( 122° F)
    B) Greater than 50, 000 foot altitude for one month
    C) Relative humidity greater than 95% Highly resistant to shock and vibration.
    Accuracy
    ± 10% of true dose for Cs-137 or Co-60 gamma.
    Rate Response
    Dosimeters are dose rate independent.

    Enclosure Material
    Barrel - carbon fiber-filled, high-strength, electrically-conducting plastic with metal clip.

    Weight
    Approx. 19 grams ( 0.7 oz.)
    Size
    PEN- 200, 500
    2mSv, 5mSv Length: 11 cm ( 4.48 inches)
    Diameter: 1.5 cm ( 0.6 inches)
    PEN- 2, 5, 20 Length: 11.5 cm ( 4.52 inches)
    Diameter: 1.5 cm ( 0.6 inches)
    Options
    Protective sapphire lens
    Warranty
    2 year limited warranty

    The Price calibration from BATAN and delivery
    The price without tax 10 %