    GD-261 PMCC Flash Point Tester

    Quantity Order:
    Origin:
    China
    Payment Method:
    Telegraphic Transfer (T/T)
    Pack. & Delivery:
    In Standard Export Case

    Specification :

    Contact: Vivienne
    Email:cqgold04@yahoo.cn
    Skype:viviennecq
    Tel:86-15123029803
    Fax:86- 023-62940030
    http://cqgold.en.hisupplier.com/

    GD-261 PMCC Flash Point Tester

    Purpose

    The instrument is designed and made as per the National Standard of People¡¯s Republic of China GB/T261-2008 ¡°Test Methods for Flash Point of Petroleum Products (Pensky-Martens Closed Cup Methods)¡±. It is suitable to determine closed cup flash point of petroleum products having a flash point higher than 40 ¡æ as per GB/T261-2008.

    Main technical specification and parameters
    1. Power supply: AC 220V¡Ã10%, 50 Hz;
    2. Heating device:
    (1) The furnace is made of SiC materials; its power is 600 W;
    (2) Heating power is adjustable in the range of 0¡«600W;
    3. Sample temperature rising rate: 1¡«12¡æ per minute, manually controlled;
    4. Electric stirring device:
    (1) Stirring motor: 45TYZ Motor;
    (2) Driving device: by a soft shaft;
    (3) Stirring blade specification: 8¡Ã40 mm;
    5. Stirring speed: As per the requirement of GB/T261-2008;
    (1) 90¡«120 RPM for procedure A;
    (2) 250¡Ã10 RPM for procedure B;
    6. Standard oil cup: As per the requirement of GB/T261-2008;
    (1) Inner diameter: 50.7¡«50.8 mm;
    (2) Depth: 55.7¡«56.0 mm;
    (3) Depth of Marked line on the oil cup: 33.9¡«34.3 mm;
    (4) Oil sample cubage: about 70 ml;
    7. Ignition device (Flame application device):
    (1) Ignition source: Coal gas (or other civilian combustible gas);
    (2) Aperture of ignition device: 0.8 mm;
    8. Thermometer: Rod type Mercury Thermometer, as per GB/T261-2008;
    (1) Temperature range: -5¡«110¡æ, Each scale division is 0.5 ¡æ;
    (2) Temperature range: 20¡«150¡æ, Each scale division is 1.0 ¡æ;
    (3) Temperature range: 90¡«370¡æ, Each scale division is 2 ¡æ;
    9. Ambient temperature: ¡Ã35¡æ;
    10. Relative humidity: ¡Ã85£¥;
    11. Total power consumption: not more than 650 W;