Welcome to Indotrade.co
Sign In | Sign Up
Priority Member Indotrade Priority
13rd Year
CV. DUTA MEDICA SARANA
CV. DUTA MEDICA SARANA
http://indotrade.co/dumedpower/
DI JUAL - BLOOD GAS ANALYZER GASTATE LENGKAP KONDISI SEKEN HARGA NEGO - EX RUMAH SAKIT SWASTA - KONDISI MULUS (0813-1590-4286)
Contact Information
Name:
Mr. Fuad Ahmad
[Marketing]
E-mail:
Homepage:
Instant Messaging:

Phone Number:
Phone number of Mr. Fuad Ahmad at Jakarta Pusat
Mobile Number:
Mobile number of Mr. Fuad Ahmad at Jakarta Pusat
Fax Number:
Fax number of Mr. Fuad Ahmad at Jakarta Pusat
Address:
RSPAD GATOT SOEBROTO. (Wartel RSPAD Gatot Soebroto, Samping radiologi) Jl. KH. Abdul Rahman Saleh No.24 - Senen Telp : 021 34834914/94522310
Jakarta Pusat, Jakarta
Indonesia
ALAT KESEHATAN, DUTA MEDIKA SARANA, HOSPITAL ONLINE STORE
Average User Review

There is no review for this company

Products Catalog

Jual > INFUSION PUMP TE-112 & SYRINGEPUMP TE-331( TERUMO JEPANG) STOK TERBATAS ! ! ![Feb. 3, 2012 8:33:48]
Price13.500.000,-
Quantity Order:
Pack. & DeliveryUnit
OriginJapan
Recommend to your friends
Specification
SYRINGE PUMP TE-331 & INFUSION PUMP TE-112 ( TERUMO JEPANG)
Specifications
Product Name
TERUFUSION Syringe Pump TE-331
TERUFUSION Syringe Pump TE-332
( with Body Weight Mode)
Compatible Syringes
10, 20, 30 and 50 mL ( TERUMO and specified brands)
Range of Flow Rate Setting
0.1-300 mL/ h ( for 10, 20 and 30 mL syringes)
0.1-999 mL/ h ( for 50 mL syringes)
0.1-1200 mL/ h ( special function for 50 mL syringes)
Flow Rate Display Change
0.1 mL/ h steps ( for settings from 0.1 to 99.9 mL/ h)
1 mL/ h steps ( for settings from 100 to 999 mL/ h)
Flow Rate Accuracy
Mechanical Accuracy: ± 1%
Accuracy including syringe: ± 3%
Occlusion Detection Pressure
Selectable from three levels.
( Values are with use of TERUMO syringe)
[ III] : 800 ± 200 mmHg max. ( 106.7 kPa ± 26.7 kPa)
[ II] : 500 ± 100 mmHg max. ( 66.7 kPa ± 13.3 kPa)
[ I] : 300 ± 100 mmHg max. ( 40 kPa ± 13.3 kPa)
Optional: 5 occlusion levels ( 100, 200, 300, 500 and 800 mmHg)
Priming ( purge rate)
300 mL/ h ~ 1200 mL/ h ( Depending on syringe size)
Alarms
Occlusion, Nearly empty, Low Battery, Plunger/ Clutch disengaged,
Syringe disengaged, AC/ DC Cable disconnected.
High flow warning when turning the dial over 10 mL/ h ( optional)
Special Functions
Functions are selectable via internal switches:
• Delivery Limit setting
0.1 – 999.9 mL ( in 0.1 mL steps)
When the limit is reached, an alarm will occur and the infusion will
continue at KVO rate of 0.1 mL/ h.
• Nearly Empty alarm setting
The time until the syringe is empty can be programmed.
( from 3 to 60 min.)
• Max. Flow Rate
1 – 1200 mL/ h ( in 1 mL steps)
• Syringe Brand Confirmation
• Memory function ( last settings)
• Changeable flow rate during infusion
Power Supply
100 to 240 VAC, 50/ 60 Hz
12 to 15 VDC
Operable duration using internal battery NiMH:
Approx. 5 hours ( using a new battery at flow rate of 5 mL/ h and
ambient temperature of 25° C, after charging at least 15 hours with
the power off)
Classification ( acc. to IEC 60601-1)
Class I and internally powered equipment, Type CF, Continuous
operation, IPX4 ( splashproof)
External Dimensions
322 ( W) x 114 ( H) x 115 ( D) mm
Weight
TE-331 ± 1.8 kg
TE-332 ± 1.9 kg
External Communication and Nurse Call Connector
RS-232 or RS-485, Nurse call : 12 VDC, 1 A max.
Display for safe parameter settings
In order to avoid reading mistakes and
misprogramming of the flow rate, the
difference between the digits and the
decimal places is clearly marked by an
orange coloured decimal point and an
apparent difference in size.
Unique dial setting
The ergonomically designed dial helps to
eliminate mistakes whilst making settings.
It allows you to reach the setting easily
and in a more evident manner.
Fast and unmistakable syringe placement
In order to guarantee correct placement
and reliable functioning of the syringe, the
pump is equipped with a barrel detection
unit. In this way, the correct placement
of different syringe sizes is very fast and
easy, as well as entirely safe.
Solid design
Especially during patient transportation,
it is important to have a system which is
designed to minimize the risk of breaking.
Therefore, it is a big advantage to have
the Terufusion syringe pumps where the
slider is always staying inside the borders
of the pump casing.
Clear alarm monitor
This monitor centralizes information
about the operation status and nature
of the alarm. The status can easily be
seen on the pump, without having to
enter menus. A pressure monitor is
incorporated in the alarm monitor to
follow the pressure variance constantly. A
large, bright Operation Indicator features
a unique flow-proportional indication for
intuitive monitoring of the flow. With its
omnidirectional view, it enhances safety in
terms of flow rate setting ( green turning) ,
Stand-by Mode ( green flashing) and alarm
status ( red) .