Welcome to
A & E Lab Instruments Co., Ltd.

Free Member
A & E Lab Instruments Co.,  Ltd.
A & E Lab Instruments Co., Ltd.
China
  • Products Catalog

    UV Vis Spedctrophotometer 16Series

    Quantity Order:
    Origin:
    China
    Payment Method:
    Telegraphic Transfer (T/T)

    Specification :

    Introduction:
    UV1601 Series are advanced Double Beam design consisting of 3 models: UV1601, UV1601A, UV1601S. All the 3 models are Stand-alone models: UV1601 with 1.8nm fixed bandwidth, UV1601A with 1nm bandwidth and UV1601S with 0.5/ 1.0/ 2.0/ 4.0nm variable bandwidth. Except bandwidth, other specifications of the 3 models are almost the same.
    The two detectors are measuring sample and reference respectively simultaneously for optimizing measurement accuracy. Basic Modes: Absorbance, Transmittance, Quantitative, Kinetics, Multi-wavelength, Wavelength Scan, DNA/ Protein test, Utility.
    Technical Specifications:
    Model: UV1601
    Optical System: Double Beam ( 1200 Lines/ mm Grating)
    Wavelength Range: 190-1100nm
    Band Width: 1.8nm
    Wavelength Accuracy: ± 0.3nm
    Wavelength Repeatability: 0.2nm
    Photometric Accuracy: ± 0.3% T
    Photometric Repeatability: 0.2% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.001A/ h @ 500nm
    Baseline Flatness: ± 0.001A
    Noise: ± 0.001A
    Stray Light: d0.05% T @ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: LCD ( 320* 240 Dots )
    Lamps: Deuterium Lamp & Tungsten Halogen Lamp
    Detector: Silicon Photodiode
    Software: UV PC Software
    Packing Size & Weight: 860× 660× 465mm & 35/ 37kg

    Model: UV1601A
    Optical System: Double Beam ( 1200 Lines/ mm Grating)
    Wavelength Range: 190-1100nm
    Band Width: 1nm
    Wavelength Accuracy: ± 0.3nm
    Wavelength Repeatability: 0.2nm
    Photometric Accuracy: ± 0.3% T
    Photometric Repeatability: 0.2% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.001A/ h @ 500nm
    Baseline Flatness: ± 0.001A
    Noise: ± 0.001A
    Stray Light: d0.05% T @ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: LCD ( 320* 240 Dots )
    Lamps: Deuterium Lamp & Tungsten Halogen Lamp
    Detector: Silicon Photodiode
    Software: UV PC Software
    Packing Size & Weight: 860× 660× 465mm & 35/ 37kg

    Model: UV1601S
    Optical System: Double Beam ( 1200 Lines/ mm Grating)
    Wavelength Range: 190-1100nm
    Band Width: 0.5nm/ 1.0nm/ 2.0nm/ 4.0nm
    Wavelength Accuracy: ± 0.3nm
    Wavelength Repeatability: 0.2nm
    Photometric Accuracy: ± 0.3% T
    Photometric Repeatability: 0.2% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.001A/ h @ 500nm
    Baseline Flatness: ± 0.001A
    Noise: ± 0.001A
    Stray Light: d0.05% T @ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: LCD ( 320* 240 Dots )
    Lamps: Deuterium Lamp & Tungsten Halogen Lamp
    Detector: Silicon Photodiode
    Software: UV PC Software
    Packing Size & Weight: 860× 660× 465mm & 35/ 37kg

    Introduction:
    UV1602/ 1603 series of spectrophotometers are advanced Single Beam design consisting of 5 models. They vary in bandwidth, wavelength accuracy and dimension. They provide excellent performance for measurements in the range of 190nm to 1100nm. All spectrophotometers features high performance sealed optics mounted on a stable machined platform.
    They are suitable for clinical lab applications, pharmaceutical and bio-chemical as well as routine applications such as: quantitative analyses, kinetics, wavelength scanning, multiple components and DNA/ Protein analysis.
    Technical Specifications:
    Model: UV1603
    Optical System: Single Beam ( 1200 Lines/ mm Grating)
    Wavelength Range: 190-1100nm
    Band Width: 1.8nm
    Wavelength Accuracy: ± 0.5nm
    Wavelength Repeatability: 0.3nm
    Photometric Accuracy: ± 0.3% T
    Photometric Repeatability: 0.2% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.002A/ h @ 500nm
    Baseline Flatness: ± 0.002A
    Noise: ± 0.001A
    Stray Light: d0.05% T @ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: LCD ( 320* 240 Dots )
    Lamps: Deuterium Lamp & Tungsten Halogen Lamp
    Detector: Silicon Photodiode
    Packing Size & Weight: 860× 660× 465mm & 25/ 35/ 36kg

    Model: UV1602
    Optical System: Single Beam ( 1200 Lines/ mm Grating)
    Wavelength Range: 190-1100nm
    Band Width: 1.8nm
    Wavelength Accuracy: ± 0.5nm
    Wavelength Repeatability: 0.3nm
    Photometric Accuracy: ± 0.3% T
    Photometric Repeatability: 0.2% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.002A/ h @ 500nm
    Baseline Flatness: ± 0.002A
    Noise: ± 0.001A
    Stray Light: d0.05% T @ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: LCD ( 320* 240 Dots )
    Lamps: Deuterium Lamp & Tungsten Halogen Lamp
    Detector: Silicon Photodiode
    Packing Size & Weight: 860× 660× 465mm & 25/ 35/ 36kg

    Model: UV1602A
    Optical System: Single Beam ( 1200 Lines/ mm Grating)
    Wavelength Range: 190-1100nm
    Band Width: 1nm
    Wavelength Accuracy: ± 0.3nm
    Wavelength Repeatability: 0.2nm
    Photometric Accuracy: ± 0.3% T
    Photometric Repeatability: 0.2% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.002A/ h @ 500nm
    Baseline Flatness: ± 0.001A
    Noise: ± 0.001A
    Stray Light: d0.05% T @ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: LCD ( 320* 240 Dots )
    Lamps: Deuterium Lamp & Tungsten Halogen Lamp
    Detector: Silicon Photodiode
    Packing Size & Weight: 860× 660× 465mm & 25/ 35/ 36kg

    Model: UV1602S
    Optical System: Single Beam ( 1200 Lines/ mm Grating)
    Wavelength Range: 190-1100nm
    Band Width: 0.5/ 1.0/ 2.0/ 4.0nm
    Wavelength Accuracy: ± 0.3nm
    Wavelength Repeatability: 0.2nm
    Photometric Accuracy: ± 0.3% T
    Photometric Repeatability: 0.2% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.002A/ h @ 500nm
    Baseline Flatness: ± 0.001A
    Noise: ± 0.001A
    Stray Light: d0.05% T @ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: LCD ( 320* 240 Dots )
    Lamps: Deuterium Lamp & Tungsten Halogen Lamp
    Detector: Silicon Photodiode
    Packing Size & Weight: 860× 660× 465mm & 25/ 35/ 36kg

    Introduction:
    UV1604/ 1605 Series are developed for precise test, its stray light is only 0.05% T.They are flexible, easy to use and maximize value. The value is evident from the performance provided every day. The local stand-alone software provide functions of Basic Mode, Quantitative Test, Kinetics and System Utilities.
    Characteristics:
    1. Large LCD screen( 128X64Dots) . Can display total 200 groups of data, 5 groups per screen. Can display standard curve and kinetics curve. System can also save the test results, total 200 groups of data and 100 standard curves can be saved in the RAM. Be Convenient for check and reload.
    2. Data can be restored after a sudden power cut. Auto setting wavelength. Tungsten lamp & deuterium lamp can be turned on/ off individually to extend lifetime. It can expand to the following functions: Quantitative, Kinetics, Wavelength Scan, Multi-wavelength & DNA/ Protein Test. Pre-aligned design makes it convenient to change lamps.
    Technical Specifications:
    Model: UV1605
    Wavelength Range: 190-1100nm
    Band Width: 2nm
    Wavelength Accuracy: ± 0.8nm
    Wavelength Repeatability: 0.3nm
    Wavelength Setting: Auto
    Photometric Accuracy: ± 0.3% T
    Photometric Repeatability: 0.2% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.002A/ h @ 500nm
    Baseline Flatness: ± 0.002A
    Noise: ± 0.001A
    Stray Light: d0.05% T @ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: LCD ( 128* 64 Dots )
    Detector: Silicon Photodiode
    Packing Size & Weight: 680× 590× 420mm & 23/ 25kg

    Model: VIS1620
    Wavelength Range: 320-1100nm
    Band Width: 2nm
    Wavelength Accuracy: ± 0.8nm
    Wavelength Repeatability: 0.3nm
    Wavelength Setting: Auto
    Photometric Accuracy: ± 0.3% T
    Photometric Repeatability: 0.2% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.002A/ h @ 500nm
    Baseline Flatness: ± 0.002A
    Noise: ± 0.001A
    Stray Light: d0.05% T @ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: LCD ( 128* 64 Dots )
    Detector: Silicon Photodiode
    Packing Size & Weight: 680× 590× 420mm & 23/ 25kg

    Model: UV1604
    Wavelength Range: 190-1100nm
    Band Width: 2nm
    Wavelength Accuracy: ± 0.5nm
    Wavelength Repeatability: 0.2nm
    Wavelength Setting: Auto
    Photometric Accuracy: ± 0.3% T
    Photometric Repeatability: 0.2% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.002A/ h @ 500nm
    Baseline Flatness: ± 0.002A
    Noise: ± 0.0015A
    Stray Light: d0.05% T @ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: LCD ( 128* 64 Dots )
    Detector: Silicon Photodiode
    Packing Size & Weight: 680× 590× 420mm & 23/ 25kg

    Model: VIS1610
    Wavelength Range: 320-1100nm
    Band Width: 2nm
    Wavelength Accuracy: ± 0.5nm
    Wavelength Repeatability: 0.2nm
    Wavelength Setting: Auto
    Photometric Accuracy: ± 0.3% T
    Photometric Repeatability: 0.2% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.002A/ h @ 500nm
    Baseline Flatness: ± 0.002A
    Noise: ± 0.0015A
    Stray Light: d0.05% T @ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: LCD ( 128* 64 Dots )
    Detector: Silicon Photodiode
    Packing Size & Weight: 680× 590× 420mm & 23/ 25kg

    Introduction:
    The UV1606/ 1607/ 1608 spectrophotometers have the most attractive cost performance. It is widely used in colleges and enterprises for general quantitative analysis and experiments.
    Characteristics:
    1. Large LCD screen( 128x64Dots) . Can display total 200 groups of data, 5 groups per screen. Can display standard curve and kinetics curve. System can also save the test results, total 200 groups of data and 100 standard curves can be saved in the RAM. Be Convenient for check and reload.
    2. Data can be restored after a sudden power cut. Auto setting wavelength. Tungsten lamp & deuterium lamp can be turned on/ off individually to extend lifetime. It can expand to the following functions: Quantitative, Kinetics, Wavelength Scan, Multi-wavelength & DNA/ Protein Test. Pre-aligned design makes it convenient to change lamps.
    Technical Specifications:
    Model: UV1608
    Wavelength Range: 190-1100nm
    Band Width: 2nm
    Optical System: Single Beam, Grating 1200line/ mm
    Wavelength Accuracy: ± 1nm
    Wavelength Repeatability: 0.5nm
    Wavelength Setting: Auto
    Photometric Accuracy: ± 0.3% T
    Photometric Repeatability: 0.2% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.002A/ h @ 500nm
    Stray Light: d0.1% T@ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: 128* 64 Dots LCD
    Lamps: Deuterium Lamp & Tungsten Halogen Lamp
    Detector: Silicon Photodiode
    Weight & Size: 680× 590× 420mm & 23/ 25kg

    Model: UV1607
    Wavelength Range: 190-1100nm
    Band Width: 2nm
    Optical System: Single Beam, Grating 1200line/ mm
    Wavelength Accuracy: ± 0.8nm
    Wavelength Repeatability: 0.3nm
    Wavelength Setting: Auto
    Photometric Accuracy: ± 0.3% T
    Photometric Repeatability: 0.2% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.002A/ h @ 500nm
    Baseline Flatness: ± 0.002A
    Stray Light: d0.05% T@ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: 128* 64 Dots LCD
    Lamps: Deuterium Lamp & Tungsten Halogen Lamp
    Detector: Silicon Photodiode
    Weight & Size: 680× 590× 420mm & 23/ 25kg

    Model: UV1606
    Wavelength Range: 190-1100nm
    Band Width: 2nm
    Optical System: Single Beam, Grating 1200line/ mm
    Wavelength Accuracy: ± 0.5nm
    Wavelength Repeatability: 0.2nm
    Wavelength Setting: Auto
    Photometric Accuracy: ± 0.3% T
    Photometric Repeatability: 0.2% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.002A/ h @ 500nm
    Baseline Flatness: ± 0.0015A
    Stray Light: d0.05% T@ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: 128* 64 Dots LCD
    Lamps: Deuterium Lamp & Tungsten Halogen Lamp
    Detector: Silicon Photodiode
    Weight & Size: 680× 590× 420mm & 23/ 25kg

    Characteristics:
    1. Large LCD screen ( 128x64 Dots) . Can display and save 50 groups of data, 3 groups per screen.
    2. Data can be restored after a sudden power cut. Auto setting wavelength.
    3. Tungsten lamp & deuterium lamp can be turned on/ off individually to extend lifetime. Automatical WL. Calibration and dark current getting.
    4. Optional software UV-Professional can expand the applications to Kinetics and Quantitatives.
    Functions:
    1. T Mode: Continuously measure the Transmittance of samples
    2. A Mode: Continuously measure the Absorbance of samples
    3. C Mode: Standard Curve method, can use at most 9 standard samples to create a new standard curve, and to measure the unknown samples by the new one.
    4. F Mode: Coefficient Method, Input the known K and C to measure the unknown concentration samples.
    Technical Specifications:
    Model: UV1609
    Optical System: Single Beam, Grating 1200line/ mm
    Wavelength Range: 200-1000nm
    Band Width: 4nm
    Wavelength Accuracy: ± 2nm
    Wavelength Repeatability: 1nm
    Wavelength Setting: Auto
    Photometric Accuracy: ± 0.5% T
    Photometric Repeatability: 0.3% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.002A/ h @ 500nm
    Stray Light: d0.3% T@ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: 128* 64 Dots LCD
    Detector: Silicon Photodiode
    Software: Optional
    Packing Size & Weight: 550× 420× 280mm & 14/ 11kg

    Model: VIS1630
    Optical System: Single Beam, Grating 1200line/ mm
    Wavelength Range: 325-1000nm
    Band Width: 4nm
    Wavelength Accuracy: ± 2nm
    Wavelength Repeatability: 1nm
    Wavelength Setting: Auto
    Photometric Accuracy: ± 0.5% T
    Photometric Repeatability: 0.3% T
    Photometric Display Range: 0-200% T, -0.3-3.0A, 0-9999C
    Stability: 0.002A/ h @ 500nm
    Stray Light: d0.3% T@ 220nm, 360nm
    Data Output Port: USB
    Printer Port: Parallel Port
    Display: 128* 64 Dots LCD
    Detector: Silicon Photodiode
    Software: Optional
    Packing Size & Weight: 550× 420× 280mm & 14/ 11kg