Specification
The Fire Extinguishing Control Panel is designated for fire protection, monitoring and control of systems for active extinguishing – gas, powder, aerosol, water, etc. After processing the signals from the automatic fire detectors and/ or manual call points the Control Panel makes commands to the executive devices for extinguishing, sound-light signalers, air conditioning and ventilation devices, etc. The Control Panel could exchange data with a repeater, PC or another intelligent device via RS 485 interfaces.

Functional data

- Control of the lines, the controllable inputs and outputs for Fault condition and automatic resetting
- Control of the lines for removed fire detector and automatic resetting
- Option for setting the evacuation time from 0 to 5 minutes
- Option for setting the time when the extinguishing device is switched on from 10 seconds to 5 minutes
- Built-in sounder for Fire condition and Fault condition with the option for switching off
- Built-in clock for astronomic time
- Test modes and setting option
- Power independent archive of 100 events registered by the Control Panel, containing the type, date and time of the event

Technical data

FIRE ALARM LINES

3

- with extinguishing control

2

- without extinguishing control

1

MAXIMUM NUMBER OF FIRE DETECTORS IN A LINE

32

CONTROLLABLE INPUTS FOR:

manual extinguishing activation

1

extinguishing keeping

1

extinguishing disable

1

mode selection

1

monitoring the extinguisher outflow

1

CONTROLLABLE OUTPUTS RELAY ( 24± 3) V DC:

for sounders in Fire condition

1

for sounders in Extinguishing status

1

for Extinguishing switching on

1

RELAY OUTPUTS SWITCHING 3À / 125V AC, 3A/ 30V DC:

for Fire condition

3

for Extinguishing

3

for Fault condition

3

OUTPUTS OPEN COLLECTOR TYPE

3

SIGNALIZATION OF REGISTERED EVENTS:

sound

built-in sounder

light

LED

text messages

LCD display, backlit

POWER SUPPLY:

mains

220/ 230V AC, 50/ 60 Hz

backup battery

2x12V DC, 12 Ah

MAXIMUM CURRENT TO EXTERNAL DEVICES

2, 5 À at ( 24± 3) V DC

OPERATING TEMPERATURE

minus 5oC to 40oC

RELATIVE HUMIDITY

( 93± 3) % at 40oC

DIMENSIONS

450x355x115 mm

WEIGHT ( EXCLUDING THE BACKUP BATTERY)

6, 6 kg