PT. SABERINDO PACIFIC - FIRE & SAFETY SPECIALIST
Free Member
PT Saberindo Pacific
Contact Information
Name:
Mr. Kusmin T [Marketing]
E-mail:
Homepage:
Instant Messaging:

Y!: kusminardy 
Phone Number:
Phone number of Mr. Kusmin T at Jakarta
Mobile Number:
Mobile number of Mr. Kusmin T at Jakarta
Fax Number:
Fax number of Mr. Kusmin T at Jakarta
Address:
Ruko Mega Grosir Cempaka Mas Blok J no.10 JL. Letjend Suprapto
Jakarta 10640, Jakarta
Indonesia
Average User Review

There is no review for this company

xxxx
Products Gallery
Language :
CHEMGUARD Mobile Foam Cart
CHEMGUARD Mobile....
Harvik - Fireman Boot
Harvik - Fireman....

Products Catalog

UNIPOS Fixed temperature heat detector FD3010
Quantity Order:
Recommend to your friends
Specification
FD 3010 Fixed temperature heat detector – The fire detector provides reliable early warning of a Fire condition upon ambient temperature reaching a fixed temperature threshold. It is available in two versions ( A2S or BS) depending on the temperature threshold in accordance with the European Standard EN 54-5.

The fire detector is suitable for premises with normal or high ambient temperature, with possible sudden changes.

Technical data

Supply voltage

( 12-30) V DC

Duty mode current

40¼ A

Fire condition current

- with a base type 3000 & 3000D

( 8-25) mA

- with a base type 3000R & 3000DR

( 18-55) mA
Terminals

For wires with cross section ( 0.8-2.5) mm2

Operating temperatures

Minus 10oC to 55oC
Sensitivity

In accordance with EN54-5, class A2S or BS
Mounting

Using bases of series 3000

Degree of detection

IP 30

Relative humidity

( 93± 3) % at 40oC

Dimensions ( base included)

Ø 106, h 48 mm

Casing material

ABS plastics, white
Weight

0.145

Protected area

Circle with diameter 10m, h 8m

3000 Standard Base – It is used upon operation with Fire Control Panels, where Fault Condition Removed detector shall be signaled as a Fault condition Interruption.

3000D Base with Schottky diode – It allows the Fire Control Panel to recognize Fault condition Removed detector from Faults condition Interruption.

3000R Base with relay output – It is used systems, where it is necessary that the activated fire detector activates additional device through the relay contact.

3000DR Base with Schottky Diode and Resistor – It is used in systems, where the activated fire detector must increase additionally the current in a line. It allows the Fire Control Panel to recognize Fault condition Removed detector from Fault condition Interruption.
You have [3] new inquiries.
Go to Member Menu
Home - Trade List - Product List - Inquiry List - Cooperation List - Company List
Copyright © 2024 Indotrade.co. All Rights Reserved.