* Mid. capacity.
Suitable for thin weighing scale.
OIML certification & NTEP approved
Specifications
Rated capacity 58.84 N{ 6 kgf} ~ 490.3 N{ 50 kgf}
Safe overload 150 % R.C.
Ultimate overload 200 % R.C.
Rated output 2 mV/ V± 0.2 mV/ V
Non-linearity 0.015 % R.O.
Hysteresis 0.015 % R.O.
Repeatability 0.02 % R.O.
Creep 0.02 % R.O./ 20 min
Creep recovery 0.02 % R.O./ 20 min
Excitation, recommended 12 V or less
Excitation, maximum 20 V
Zero balance ± 0.1 mV/ V
Input resistance 420 ©
Output resistance 350 © ± 5 ©
Insulation resistance 2 000 M© or more ( DC50 V) ( between bridge and main body)
Temp. range, compensated -10 ~ 50
Temp. range, safe -10 ~ 50
Temp. effect on zero 0.04 % R.O./ 10
Temp. effect on output 0.012 % LOAD/ 10
Cable Æ 3.2, 4-cores shielded 40 cm cable directly attached and cable ends is separated.
Class of protection IP64
Material of element Alluminium alloy
Durability 1 000 000 times with rated load applied
Effect of eccentric load û C2G1-6K to 35K
- Size of loading plate is 300 mm x 300 mm at maximum.
- The center of loading plate and the center of load cell should be the same position
- Error is within 0.02 % R.O. applied with 1/ 2 of rated capacity at the position of 75 mm of eccentricity.