Welcome to
Xiamen Richocean Imp. & Exp. Co., Ltd.

Free Member
Xiamen Richocean Imp. & Exp. Co.,  Ltd.
Xiamen Richocean Imp. & Exp. Co., Ltd.
China
  • Products Catalog

    Safety Barrier

    Price:
    USD
    Quantity Order:
    Origin:
    China
    Payment Method:
    Telegraphic Transfer (T/T)
    Pack. & Delivery:
    box, carton

    Specification :

    Intrinsic Safety Barrier
    Single-channel or dual-output or two-channel
    4-20mA or 1-5V or thermocouple or RTD or Switch or Resistance or Frequency input, Hart, Alarm Driver
    DC signal one-channel Input, one-channel isolating output
    DC signal source used to connect various site intrinsic safety equipments
    Introduction Main Technical Specifications
    DC signal converter safety barrier
    DC signal converter safety barrier input DC signal from the hazardous
    Areas, and outputs DC current or voltage signal to control system or other
    Instruments in safe-area after isolation and interference suppression.
    The safety barrier adopts independent DC power supply,
    Power supply-input-output isolated.
    Power supply
    Power voltage: 20~ 30VDC
    Power indicator: Power LED lights on: Green
    Current consumption
    ( when 24VDC is supplying) : < 25mA ( single-channel)
    < 40mA ( single-channel, dual-output)
    < 50mA ( dual-channel, dual-output)
    Input form hazardous-area
    Input current: 4~ 20mA; 0~ 20mA; 0~ 10mA; Other specified current
    Input voltage: 1~ 5V; 0~ 5V; 0~ 10V; Other specified voltage
    Input impedance: Current input 50& Omega; ; Voltage input ³ 500K& Omega;
    Output to safe-area
    Output current: 4~ 20mA; 0~ 20mA; 0~ 10mA; Other specified current
    Output voltage: 1~ 5V; 0~ 5V; 0~ 10V; Other specified voltage
    Allowed output load: 0~ 550& Omega; ( Power ³ 22VDC at full load of 550& Omega; )
    Voltage output impedance: 500& Omega;
    Output ripple: < 10MVP-p
    General technical parameters
    Transmission error: ± 0.1%
    Temperature drift: ± 0.015% / ° C
    Startup response time: < 1s ( 10~ 90% )
    Power change error: ± 0.1% ( allowed voltage scope 20~ 30VDC)
    Dielectric strength: Input-output-power 2.5KV, 1min, 50Hz
    Insulation resistance: Input-output-power ³ 100M& Omega; / 500VDC
    Operating temperature: -20~ + 60° C
    Dimension: Width × Height × Length= 16× 116× 110( mm)
    Safe explosion-proof parameters
    Explosion-proof grade mark: [ Exia] IIC
    Safety parameters: Um = 250V Uo = 10.5V Io = 6mA
    Po = 15.8mW Lo = 10 mH Co = 1.6mF
    Which Widely used in:
    Oil, Gas, Chemical, Petrochemical, Semiconductor, Metallurgy, Machinery, Cement, Iron & Steel, Textile, Tyre, Plastic, Glass, Pulp & paper, medicine, food ( sugar, beverage) factory
    Intrinsic Safety Barrier Intrinsic Safety Barrier Alarm Driver.