Universal Vibration Meter ( Model- 1607)[May. 30, 2011 23:14:52]
VIBRATION METER MODEL- 1607 UNIVERSAL VIBRATION METER .
" General- purpose type small vibrometer capable of measuring three modes of acceleration, velocity and displacement" .
" Wide- band and capable of measuring from a minute level to a large level" .
" Maneuverable in field measurement because of the small size and use of dry cells" .
" Capable of selecting a band matching a measurement object because of the built- in high- pass/ low- pass filter" .
" Capable of wave analysis and level recording with the attached AC and DC output terminals" .
" Capable of appropriately using various sensors with ease by the easy setting of the sensor s sensitivity
" Capable of using a remote charge converter and a detector with a built- in preamp in addition to an ordinary charge- output type detector" .
Specifications:
- Charge Input Connector ( BNC Connector on the front panel)
Pickup Sensitivity ( pC) : PU SENS× 1: 1.00- 9.9pC/ G
: PU SENS× 10: 10.0- 99.9pC/ G
Max input charge : 10, 000pC
- Voltage Input Connector ( BNC Connector on the real panel)
Pickup Sensitivity ( mV) : PU SENS× 1: 1.00- 9.99mV/ G
: PU SENS× 10: 10.0- 99.9mV/ G
Max input : ± 10V
Supply current : 0.4- 4mA ( internal volume)
- Remote Charge Converter Input ( Option)
Pickup Sensitivity ( mV) : PU SENS× 1: 1.00- 9.99mV/ G
: PU SENS× 10: 10.0- 99.9mV/ G
Max input voltage : ± 10V
- Output
Indicator : Provided with dual scale 0- 1, 0- 3 to indicate the
magnitude of amplitude selected : with the meter selector
or battery voltage.
Overload lamp : When the linear range is exceeded in the internal circuit, LED lamp is on.
AC OUT( BNC) : Vibration waveform output
: ± 1V/ FS Output resistance 100© 5mA Max.current
DC OUT( BNC) : Trend recording as level output
: 0- 1VDC Output resistance 100© 5mA Max.current
- Measuring Range
ACC1( G) : 1Hz- 50kHz( 1dB) , 2Hz- 20kHz( 0.5dB)
: PU SENS× 10: 0.0316/ 0.1- 100/ 316/ FS
: PU SENS× 1: 0.316/ 1- 1000/ 3160/ FS
ACC2( m/ s2) : 1Hz- 50kHz( 1dB) , 2Hz- 20kHz( 0.5dB)
: PU SENS× 10: 0.316/ 1- 1000/ 3160/ FS
: PU SENS× 1: 3.16/ 10- 10000/ 31600/ FS
VEL( cm/ s) : 3Hz- ( 0.5dB)
: PU SENS× 10: 0.316/ 1- 1000/ 3160/ FS
: PU SENS× 1: 3.16/ 10- 10000/ 31600/ F
DISP( mm) : 3Hz- ( 0.5dB)
: PU SENS× 10: 0.1/ 0.316- 316/ 1000/ FS
: PU SENS× 1: 1/ 3.16- 3160/ 10000/ FS
DISP2( mm) : 10Hz- ( 0.5dB)
: PU SENS× 10: 0.01/ 0.0316- 31.6/ 100/ FS
: PU SENS× 1: 0.1/ 0.316- 316/ 1000/ FS
- Filter
High- pass filter( Hz) : OUT( 1Hz) / 3/ 10/ 30/ 100
Low- pass filter( Hz) : 300/ 1k/ 3k/ 10k/ OUT( 50KHz)
- The Others
Accuracy : Within 3% at 80Hz, 100pC input
Cal signal : 80Hz, ± 1V max. sinusoidal wave
Power supply : Dry cell LR6× 4( DC6V)
: Continuous use more than 5 hours
Temperature, Humidity: 0- 50º C, 90 % RH max.
Contact Us :
Website: www.vibrasindo.com
Email: sales@ vibrasindo.com