Specification :
Features:
1. The first ICU ventilator with CE mark in China
2. Pneumatically driven and electronically control for child and adult
3. Detachable 10.4â TFT color screen decrease cross-infection effectively
4. Easy setting by navigator wheel knob & touch key
5. Three-level light and sound alarm, with concise words describing problems
6. Sensitive pressure trigger and flow trigger with base flow
7. Lung mechanics monitoring and loops
8. Emergency start function
9. Synchronized nebulizer ( Option)
10. Inspiratory and expiratory hold ( Option)
11. Manual inspiration ( Option)
12. 100% O2 ( Option)
13. Built-in inspiration and expiration flow sensor, durable and water coagulation resistant
14. Built-in battery
Technical Specifications
Modes of Ventilation
1. Volume Controlled ( VCV) , Assist/ Control
2. Pressure Controlled ( PCV) , Assist/ Control
3. Synchronized Intermittent Mandatory Ventilation ( SIMV)
4. Volume-controlled breaths ( V-SIMV)
5. Pressure- controlled breaths ( P-SIMV)
6. Pressure Support ( PSV)
7. Spontaneous ventilation ( SPONT)
8. Continuous Positive Airway Pressure ( CPAP)
9. Combined: VCV + SIGH, SIMV ( VCV) + PSV, SIMV ( PCV) + PSV
Parameter
1. Tidal volume: 50~ 1500ml
2. Respiratory rate: 4~ 100bpm( used in VCV & PCV)
1~ 40bpm ( used in V-SIMV & P-SIMV)
3. Inspiration time: 0.1~ 12s
4. Inspiratory pause time: 0~ 4s
5. FiO2: 21% ~ 100%
6. Trigger sensitivity: Pressure ( -2~ 0kPa, above PEEP)
Flow ( 0.5~ 20LPM, with base flow)
7. PEEP: 0~ 4kPa
8. Psupport: 0~ 6kPa
9. Pcontrol: 0.5~ 6kPa
10.E-sense ( Option) : 10% ~ 50%
11. 100% O2 ( Option) : 2min
12. Inspiratory hold ( Option) : Yes
13. Expiratory hold ( Option) : Yes
14. Manual inspiration ( Option) : Yes
15. Freeze ( Option) : Yes
16. Nebulizer: 30 minutes
17. Emergency start: Yes
18. Key lock: Yes
Monitoring
1. Pressure values: Paw, Pplat, Pmean, PEEP
2. Volume/ Flow values: VTI, VTE, MV, MVspont
3. Time values: Ftotal, Fspont, I: E
4. Oxygen monitoring: With O2 sensor ( option) , without O2 sensor
5. Real time curves: Pressure - Time, Flow - Time, Volume -Time, Pressure - Volume loop, Flow - Volume loop
6. Respiratory mechanics, dynamic and static compliance, resistance, auto PEEP
Alarm
MV high, MV low, Circuit disconnect, Paw high, Paw low, Airway pressure continue high, VTE high, Fspont high, Tapnea, FiO2 low, FiO2 low, Power supply failure, Nebulizer on, Battery low, Battery exhausted, Air supply down, O2 supply down, Air & O2 supply down
Technical data
1. Screen: 10.4â TFT color screen ( detachable)
2. Gas supply: O2 , Air ( All gas must be medical level) , 0.28~ 0.6MPa
3. Power supply: AC110~ 240V, 50Hz/ 60Hz, 65VA
4. Maximum security pressure: 8kPa
5. Compliance: 4mL/ 100Pa
6. Noise: 65dB( A)
7. Communication interfaces: RS232 port, VGA port
8. Dimensions( HÃ WÃ D) : 400Ã 303Ã 250mm
9. Weight: 15kg