Language :

Sell

JENCO 6303C, 1/ 4 DIN panel mount pH controller[Oct. 29, 2010 1:49:20]
Priceinquiry
Quantity Order:
Payment MethodTelegraphic Transfer (T/T)
Quantity1 unit
Pack. & Deliveryunit & franco jabodetabek
OriginUnited States
JENCO 1/ 4 DIN panel mount pH controller
Model : 6303C

Description
1/ 4 DIN panel mount pH controller, microprocessor based with membrane type keypad and password protection. Meter has a programmable, reversible and isolated 4- 20 mA current output and dual SPDT relays. Connectors are a BNC and spade lug terminal blocks. ATC is a 10K thermistor or simulation resistor. Features a NEMA-4 type bezel for watertight seals against mounting panels. 115/ 230V AC.

* High accuracy, reversible & isolated 4-20 mA current out
* Set point security code protection
* Dual output relays
* Automatic/ manual temp. compensation
* Dual output relays
* Automatic/ manual temp. compensation
* User programmable buffer recognition or pre-stored nbs buffers
* Low drift & high stability
* User friendly keypad format
* CE approved version available
* Power down memory backup
* 1/ 4 DIN housing
* User programmable relay hysteresis
* Nema 4 bezel

Specifications

*
Range Resolution Accuracy
pH -2.00 to 16.00 pH 0.01 pH ± 0.01 pH
ORP -1999 to 1999mV 1 mV ± 0.1%
Temp. -3.0 to 115.0 ° C 0.1 ° C ± 0.2 ° C
*
General
o Input impedance: > 10exp( 13) ohms
o Temp. compensation: Auto/ manual 0 to 115.0 ° C
o Electrode buffer recognition: 4.00, 6.86, & 10.01
o Single point standardization: Eliminates electrode offset
o Dual point standardization: Calculates/ compensates for electrode solpe & offse
o Bumpless calibration: Controller output does not change during calibrati
o Display: 0.5 inch high LCD
o Lock: Set values connot be changed duless lock code is e
o Relay set point hysteresis: User programmable
o Relay output ( resistive load) : 5amp. at 115 VAC, 2.5 amp. at 230 VAC
o CE certification: Effective january, 1998
o NEMA 4: Front of the mounting panel
o Power failure backup: Yes
o Dimensions: 1/ 4 DIN case
o Weight: 680 g
o Power source: 115 VAC, 230 VAC ± 15% 50/ 60 hz