COATING THICKNESS TESTER CT.130 depolabco7@ gmail.com[Nov. 20, 2015 7:40:24]
Coating Thickness Gauge CT 130
Object of Measuring: This compact gauge can be used for non-destructive coating thickness measurement of non-magnetic coatings, e.g. paint, enamel, chrome on steel, and insulating coatings, e.g. paint and anodizing coatings on non-ferrous metals.
2 in 1 Probe: The internal probe can work on both principles, magnetic induction and the eddy currents. The probe can automatically detect the substrates type ( Magnetic or not) , and calculate the coating thickness and display it fast.
Display: 128* 128 dot matrix LCD display, standard menu operations;
Measure Mode: single and continuous available;
Two group mode: direct ( DIR) and general( GEN) , readings will be lost when power off in DIR mode, and not be lost in GEN mode. 80 readings can be stored for each group;
Calibration: Zero point calibration and multi-point calibration( up to 4 points) for each group;
Data Management: User can recall, delete specified readings, or delete group readings;
Statistics display: Simultaneously display Measuring Value, mean, minimum, maximum and standard deviation;
Three probe mode: auto, magnetic and eddy current;
Alarm: User can set high or low limit alarm for each group;
Power Save: Power off automatically;
PC Connectable: USB interface to data transmission; Download readings via PC with EasyCoating Software.
SPECIFICATIONS :
ü Measuring principle: Magnetic induction ( F-probe) and eddy current ( N-probe) ;
ü Measuring range: 0 to 1300um ( 0 to 51.2mils) ;
ü Accuracy: ± ( 3% of readings+ 2um) ;
± ( 3% of readings+ 0.078mils) ;
ü Resolution: 0um~ 999um ( 1um) , 1000um~ 1300um ( 0.01mm) ;
0mils~ 39.39mils ( 0.01mils) , 39.4mils~ 51.2mils ( 0.1mils) ;
ü Calibration: One to four point calibration, zero calibration;
ü Data Group: One direct group ( readings not be stored to memory) , four general group ( readings can be stored) , and each group have individual statistics, alarm settings and calibration;
ü Statistics: No. of readings, mean, minimum, maximum and standard deviation;
ü Units: um, mm and mils;
ü Alarm: User can set the high/ low alarm, and alarm icon displayed on LCD when over the limit;
ü Minimum curvature radius: convex 1.5mm( 59mils) and concave 25mm( 984mils) ;
ü Minimum measuring size: Diameter 6mm( 236mils) ;
ü Minimum thickness of substrate: F-probe: 0.5mm( 0.02" ) , N-probe: 0.3mm( 0.012" ) ;
ü Computer interface: Download data via USB interface;
ü Power supply: Two 1.5v AAA battery;
Operation temperature: 0º C to 40º C( 32º F to 104º F) ;
Storage temperature: -20º C to 70º C( -4º F to 158º F) ;
Size: 110mm* 53mm* 24mm ( 4.33" * 2.09" * 0.94" ) ;
Weight: 92g ( 3.24oz) ;