Welcome!
Join Now
|
Member Sign In
Member Menu
|
Help
|
0
ALL
PRODUCT
SELL
INQUIRY
COMPANY
Recommend Indotrade.co to a friend
*
means required information
*
Your Name:
*
Your Email:
*
Your Friend's Email: :
To send to more than one person, separate addresses with a comma.
Example: name1@domain.com, name2@domain.com etc.
*
Comment:
Hi, I am Businessman I found this sample from https://www.indotrade.co and think it might be useful to you. ------------------------------------------------------- HANNA, HI 93102 Complete Instrument for Turbidity, Cyanuric Acid, Bromine, Chlorine, Iron, Iodine and pH The most important parameters needed for water analysis, especially in drinking water are now available in a portable meter. You can obtain lab performance in the field by using the HI 93102. It not only measures turbidity, but also pH, total and free chlorine, bromine, iodine, iron and cyanuric acid ( CYS) . All this in the palm of your hand and in seconds! Measurements are made quickly and repeatedly through a sophisticated, yet easy-to-use microprocessor. In colorimetric mode, users can select between factory preprogrammed calibration or calibrating the meter on their own, and measure either concentration or relative absorbance of the sample. Up to 25 measured samples can be stored in memory together with time and date. Range Turbidity 0.00 to 9.99 FTU; 10.0 to 50.0 FTU Range Bromine 0.00 to 8.00 mg/ L Range Free & Total Chlorine 0.00 to 2.50 mg/ L; 0.00 to 3.50 mg/ L Range Cyanuric Acid 0 to 80 mg/ L Range Iodine 0.0 to 12.5 mg/ L Range Iron LR 0.00 to 1.00 mg/ L Range pH 5.9 to 8.5 pH Resolution Turbidity 0.01; 0.1 FTU Resolution Bromine 0.01 mg/ L Resolution Free & Total Chlorine 0.01 mg/ L Resolution Cyanuric Acid 1 mg/ L Resolution Iodine 0.1 mg/ L Resolution Iron LR 0.01 mg/ L Resolution pH 0.1 pH Accuracy Turbidity ± 0.5 FTU ± 5% of reading Accuracy Bromine ± 0.08 mg/ L ± 3% of reading Accuracy Free & Total Chlorine ± 0.03 mg/ L ± 3% of reading Accuracy Cyanuric Acid ± 1 mg/ L ± 15% of reading Accuracy Iodine ± 0.1 mg/ L ± 5% of reading Accuracy Iron LR ± 0.02 mg/ L ± 3% of reading Accuracy pH ± 0.1 pH Calibration 2 points, selectable between 0.00 - 50.0 FTU ( 0.00 and 20.0 FTU recommended) Light Source Green LED Light Life life of the instrument Light Detection 2 Silicon Photocells Battery Type / Life 4 x 1.5V AA / approx. 60 hours of continuous use or 1000 measurements; automatic shut-off after 10, 20, 30, 40, 50 or 60 minutes ( User-Selectable) Environment 0 to 50° C ( 32 to 122° F) ; RH max 95% non-condensing Dimensions 220 x 82 x 66 mm ( 8.7 x 3.2 x 2.6" ) Weight 510 g ( 1.1 lb.) For detailed information, please go to http://www.indotrade.co/karuniamakmur/2422234
0.0106 194.163.150.105