Welcome!
Join Now
|
Member Sign In
Member Menu
|
Help
|
0
ALL
PRODUCT
SELL
INQUIRY
COMPANY
Recommend Indotrade.co to a friend
*
means required information
*
Your Name:
*
Your Email:
*
Your Friend's Email: :
To send to more than one person, separate addresses with a comma.
Example: name1@domain.com, name2@domain.com etc.
*
Comment:
Hi, I am Businessman I found this sample from https://www.indotrade.co and think it might be useful to you. ------------------------------------------------------- STANHOPE SETA, Selby Noack Volatility Test36004 Evaporation Loss - Volatility collection of Lubricating oils. Methods & Specifications: ASTM D 5800, ILSAC GF-3, GF-4; API ‘ SL’ , ‘ SM’ specifications for modern engine oils. The original Noack evaporation loss test has been known and used in the industry since the 1930’ s. It uses a toxic mixture of compounds known as Wood’ s Metal for sample heating. In the mid-1990’ s, Mr. Selby and his co-workers at Savant, Inc. eliminated the need for Wood’ s Metal by devising a noble-metal heater approach. When thorough developmental work on the Selby-Noack was completed in 1997, Tannas began marketing the first non-Wood’ s Metal Noack tester. In addition to its D 5800 precision and dramatically smaller footprint, the Selby-Noack has a major advantage in being able to collect all the volatiles emitted by the test. Analysis of the physical and chemical properties of these volatiles is important, for example, in determining the transport of phosphorus and sulfur compounds which prematurely degrade the exhaust system catalyst control of emissions. Dimensions: - Bench-top ( 16" ( w) x 17" ( d) x 18.5" ( h) ) or ( 41 x 43 x 47 cm) Weight: - ~ 50 lbs. ( 23 kg) Voltage: -120 VAC, Single Phase, 15 Amp., 60 Hz. ( Also available in 220 VAC and 50 Hz) Operating Parameters: - Programmable Temperature Controller: 250° C ( ± 0.1° C) - Sample Volume: 65 grams - Test Duration: 1 hour ( automatic shut-off) Heating Medium: - Noble-Metal Electric Heater ( Eliminates the use of toxic Wood' s Metal) Vacuum Control: - Automated Vacuum control ( ± 0.1 cm of H2O) - Built-in Vacuum Pump Special Features: - Patented coalescing system to allow collection of volatilized material for further analyses, such as the Phosphorus Emission Index ( PEI) . - Digital ( RS232) Output Ready for monitoring of both Temperature and Vacuum via printer ( Analog output to chart recorder available upon request.) For detailed information, please go to http://www.indotrade.co/karuniamakmur/2439517
0.0086 194.163.150.105