Features: 200000 lux/ 20000FC lux and FC switchable date hold and peak hold over-input indication of ' 1' Specification: 3 1/ 2 digits 18mm LCD Range: 0.1~ 200, 000Lux/ 0.01~ 20, 000FC ....
Our company were selling Security, Laboratory and industries products, rubber boat, flowmeter, current meter
Infrared Thermometer AR872 Temperature Range : -50 º C to 1, 250 º C Accuracy :  ± 2% or  ± 2 º C Distance Spot Ratio : 30 : 1 Distance Spot Ratio : 30 : 1 Resolution : 0.1 º C for 1, 000 º C ....
Temperature Range : -50 º C to 850 º C Accuracy :  ± 1.5% or  ± 1.5 º C Distance Spot Ratio : 12 : 1 Emissivity : 0.10 ~ 1.00 adjustable Resolution : 0.1 º C for < 1, 000 º C Response time & ....
Features & Applications: This dependable Protimeter Mini utilizes the triedand-tested pin method of moisture measurement. Its ergonomic, compact design incorporates 60 bright green, yellow and....
LM802 SPECIFICATION Display Measuring Range: * 200 Lux * 2, 000 Lux * 20, 000 Lux * 200, 000 Lux * ( 20, 000 Lux range reading X10) * 200, 000 Lux range reading X10 * 20; 200; 2000; ....
Measuring Range: 0Â º C~ 45Â º C Wind Speed Measuring Range: 0.3~ 45m/ s Wind volume Range: 0~ 9999m3/ s Accuracy of Wind speed: Â ± 3% Â ± 1dgts Wind Speed Unit Selection: M/ s, Ft/ min, Knots, Km/ ....
SPECIFICATIONS Measuring Range: 1~ 100.000lux Accuracy:  ± 4 %  Unit Selection: lux  Measure Level Selection: Manual  Repeatability:  ± 2%   Sampling Frequency: 2 time/ sec ....
SPECIFICATION Wide range measurement Accurate measuring Data hold Relative Function Lux/ Fc selectable ( 1Fc= 10, 76Lux) Repeatibility  ± 2% Measuring Range : 1 to 200, 000 Lux Accuracy: ....
Infrared Thermometer AR882 Temperature Range : -18 º C to 1, 500 º C Accuracy :  ± 2% or  ± 2 º C Distance Spot Ratio : 50 : 1 Emissivity : 0.10~ 1.00 adjustable Resolution : 0.1 º C for 1, ....
NON CONTACT THERMOMETER - INFRARED TEMPERATURE METER BMST530 Specification: Temperature Range: -32Â º c to 530Â º C Accuracy: Â ± 2% + 2Â º C Distance Spot Ratio: 12 : 1 Emissivity: 0.95 ....
Type: DT602 Temp. Range: -32 ~ 320  º C ( -25 ~ 608 º F ) Resolution: 0. 1  º C/ 0. 1  º F Accuracy:  ± 0  º C or  ± 2% Emissivity: Preset at 0. 95 Field Of View ( D: S) : 12: 1 Response....
Magnehelic Differential Pressure Gage - Series 2000-6MM Differential pressure gage, range 0-6 mm w.c., calibrated for vertical scale position. Series 2000 Magnehelic ® Differential Pressure Gage....
Display: LCD display Standard: IEC651 Type2, ANSIS1.4Type2 Parameters measured: SL, Leq, LN Measuring range: A. 30-130dB C. 35-130dB Line. 35-130dB Detection characteristics: Fast/ Slow ....
Hygro-Thermometer Extech 445713 Max/ Min with " reset" function Humidity: 10 to 99% RH Temperature: 14 to 140Â ° F or -10 to 60Â ° C Accuracy: Â ± 5% RH; Â ± 1.8Â ° F, Â ± 1Â ° C Hp. 081216635083, ....
Hygro-Thermometer Extech 445703 Max/ Min with " reset" function Humidity: 10 to 99% RH Temp: 14 to 140Â ° F or -10 to 60Â ° C Accuracy: Â ± 5% RH; Â ± 1.8Â ° F, Â ± 1Â ° C