Specifications Range 0.00 to 2.00 mg/ L Hâ € š Oâ € š ; 0.0 to 10.0 mg/ L Hâ € š Oâ € š Resolution 0.25 mg/ L ( 0.00 to 2.00 mg/ L range) ; 1.0 mg/ L ( 0.0 to 10.0 mg/ L range) Method iodometric ....
Specification: Method Titration Range 40-500 mg/ L Smallest Increment 20 mg/ L Chemical Method EDTA Number of Tests approx 50 Weight 120 g
Specifications Range 0.0 to 3.0 mg/ L ( ppm) Resolution 0.6 mg/ L ( ppm) Method DPD Number of Tests 60 CTK Type Colorimetric Ordering Information HI3830 test kit comes with 30 mL....
Specifications Range 0.0 - 20.0 ppm Resolution 0.1 ppm Accuracy @ 25 ° C/ 77 ° F  ± 6% of reading  ± 0.5 ppm Light Source LED @ 470 nm Light Detector silicon photocell Method ....
Specifications Range 0 - 999 ppb Resolution 2 ppb Accuracy @ 25 ° C/ 77 ° F  ± 5% of reading  ± 10 ppb Light Source LED @ 575 nm Light Detector silicon photocell Method adaptation....
Specifications Range 0.00 - 2.70 ppm Resolution 0.01 ppm Accuracy @ 25 ° C/ 77 ° F  ± 5% of reading  ± 0.20 ppm Light Source LED @ 525 nm Light Detector silicon photocell Method ....
Specifications Range 0.00 - 2.00 ppm Resolution 0.01 ppm Accuracy @ 25 ° C/ 77 ° F  ± 5% of reading  ± 0.20 ppm Light Source LED @ 525 nm Light Detector silicon photocell Method ....
Specifications Range 0.0 - 20.0 ppm Resolution 0.01 ppm Accuracy @ 25 ° C/ 77 ° F  ± 5% of reading  ± 0.2 ppm Light Source LED @ 525 nm Light Detector silicon photocell Method ....
Specifications Range 0.00 - 5.00 ppm Resolution 0.01 ppm Accuracy @ 25 ° C/ 77 ° F  ± 3% of reading  ± 0.03 ppm Light Source LED @ 525 nm Light Detector silicon photocell Method ....
Specifications pH Range -2.000 to 20.000 pH pH Resolution 0.1, 0.01, 0.001 pH pH Accuracy ( @ 25Â º C/ 77Â º F) Â ± 0.1 pH, Â ± 0.01 pH, Â ± 0.002 pH Â ± 1 LSD pH Calibration automatic, up to....
SPECIFICATIONS: Range 0.0 to 199.9 Â µ s/ cm; 0 to 1999 Â µ s/ cm; 0.00 to 19.99 ms/ cm; 0.0 to 199.9 mS/ cm Resolution 0.1 Â µ s/ cm; 1 Â µ s/ cm; 0.01 mS/ cm; 0.1 mS/ cm Accuracy ( @ 20Â ° C/ 68Â ° ....
Specification: Range 0.0 to 199.9 Â µ s/ cm; 0 to 1999 Â µ s/ cm; 0.00 to 19.99 ms/ cm; 0.0 to 199.9 ms/ cm Resolution 0.1 Â µ s/ cm; 1 Â µ s/ cm; 0.01 ms/ cm; 0.1 ms/ cm EC Accuracy ( @ 20Â ° ....
Specification: Range pH 0.00 to 14.00 pH ORP Â ± 1999 mV Temperature 0.0 to 100.0Â ° C Resolution pH 0.01 pH ORP 1 mV Temperature 0.1Â ° C Accuracy pH Â ± 0.01 pH ORP Â ± 1....
Specification: Reference double, Ag/ AgCl Junction/ Flow Rate cloth Electrolyte gel Max Pressure 3 bar Range pH: 0 to 13 Recommended Operating Temp. 20 to 40Â ° C ( 68....
Speciification: Reference Double, Ag/ AgCl Junction/ Flow Rate ceramic, single / 15-20 Â µ L/ h Electrolyte KCl 3.5M Max Pressure 0.1 bar Range 0 to 13 pH; 20 to 40Â ° C ( 68....