pH Range 0.00 to 14.00 pH pH Resolution 0.01 pH pH Accuracy  ± 0.2 pH Calibration manual, two points pH Electrode HI1270 ( included) Battery Type/ Life 1.5V ( 2) / approximately....
ange 0 to 200 ppb Resolution 1 ppb Accuracy @ 25 ° C/ 77 ° F  ± 10 ppb  ± 4% of reading Light Source LED @ 525 nm Light Detector silicon photocell Method adaptation of the EPA....
Range 0 to 200 ppm Resolution 1 ppm Accuracy @ 25 ° C/ 77 ° F  ± 2 ppm  ± 5% of reading Light Source LED @ 470 nm Light Detector silicon photocell Method adaptation of the USEPA....
Range 0 to 500 PCU Resolution 5 PCU Accuracy @ 25Â ° C/ 77Â ° F Â ± 10 PCU Â ± 5% of reading Light Source LED @ 470 nm Light Detector silicon photocell Method adaptation of the Standard....
Conductivity Range 0.00 to 4.00 mS/ cm ( dS/ m) * Conductivity Resolution 0.01 mS/ cm Conductivity Accuracy  ± 0.05 mS/ cm ( 0.00 to 2.00 mS/ cm) ,  ± 0.30 mS/ cm ( 2.00 to 4.00 mS/ cm) ....
pH Range -2.00 to 16.00 pH pH Resolution 0.01 pH pH Accuracy  ± 0.05 pH ORP Range  ± 1000 mV ORP Resolution 1 mV ORP Accuracy  ± 2 mV Temperature Range -5.0 to 60.0 ° C / 23.0 to....
ORP Range  ± 1000 mV ORP Resolution 1 mV ORP Accuracy  ± 2 mV Temperature Range -5.0 to 60.0 ° C / 23.0 to 140.0 ° F Temperature Resolution 0.1 ° C / 0.1 ° F Temperature Accuracy  ± ....
ORP Range  ± 999 mV ORP Resolution 1 mV ORP Accuracy  ± 5 mV Battery Type/ Life 1.5V ( 4) / approximately 700 hours of continuous use Environment 0 to 50 ° C ( 32 to 122 ° F) ; RH max....
Light Source up to 5 tungsten lamps with different narrow band interference filters. Light Detector silicon photocell Power Supply external 12 VDC power adapter or built-in rechargeable....
Order Information: HI 902C1-01 ( 115V) titrator with one analog board HI 902C1-02 ( 230V) titrator with one analog board HI 902C2-01 ( 115V) titrator with two analog boards HI 902C2-02 ( 230V) ....
Range HI 147-00 -50.0 to 150.0Â ° C HI 147-01 -58.0 to 302.0Â ° F Resolution HI 147-00 0.1Â ° C HI 147-01 0.1Â ° F ( -58.0 to 199.9Â ° F) 1Â ° F ( 200 to 302Â ° F) Accuracy HI 147-00 ....
The HI93701-01 are reagents for the colorimetric determination of free chlorine. There are enough reagents for 100 tests and are for use with Hannaâ € ™ s compatible benchtop and portable photometers.....
Email to a Friend Share Facebook Share on Twitter Be the first to review this product Ships within 1-2 Business Days The HI93721-01 are reagents for the colorimetric determination of iron.....
The HI93711-01 are reagents for the colorimetric determination of total chlorine. There are enough reagents for 100 tests and are for use with Hannaâ € ™ s compatible benchtop and portable photometers.....