BathrobeBatikBeddingBedding BlanketBedding OthersBedding PillowBedding QuiltBedding SetBedding Sheet & CoverBlend FabricsBulk TextileCarpetsChemical FabricsCooperation & InvestmentCotton FabricsCurtain, VitrageCushionDenim & Jean FabricsEmbroidery & Craft TextileFeather & Down Raw MaterialsFur Raw MaterialsGarmentGrey FabricsHousehold Textile ProductHousehold Textile Product - OthersIndustrial FabricsInterweave FabricsKnitting FabricsLeather ProductsLinen, Ramie, HempNon-woven ClothOthers Textile ProductsRope, Twine, WebbingRug & MatSilkSlices TextileTable ClothTextile AccessoriesTextile AgentsTextile Lab EquipmentTextile Machinery & PartsTextile Materials: CottonTextile Materials: Leather Raw MaterialsTextile Materials: LinenTextile Materials: OthersTextile Materials: RayonTextile Materials: SilkTextile Materials: Synthetic fibresTextile Materials: VelvetTextile Materials: WoolTextile ProcessingTextile StocksTextile WasteThreadTowel & HandkerchiefUpholstery TextileWool FabricsYarn
rss RSS: Textile Lab Equipment
Result 1-15 of 22
Jual HI 8424 Portabel pH meter  Apr. 22, 2015 0:36:50

Order Information: HI 8424 is supplied with HI 1230B pH electrode, HI 7669AW temperature probe, calibration and cleaning solution, battery, protective case and instructions. Specifications MSDS....

  • See more »
  • HI 935005N K-Type Waterproof Thermocouple Thermometer with Calibration Feature  Apr. 21, 2015 23:46:19

    Range -50.0 to 199.9Â ° C; 200 to 1350Â ° C; -58.0 to 399.9Â ° F; 400 to 2462Â ° F Resolution 0.1Â ° C ( -50.0 to 199.9Â ° C) ; 1Â ° C ( outside) ; 0.1Â ° F ( -58.0 to 399.9Â ° F) 1Â ° F ( outside....

  • See more »
  • HI 93510N Waterproof Thermistor Thermometer with Calibration Feature  Apr. 21, 2015 23:41:33

    Range -50.0 to 150.0 ° C; -58.0 to 302.0 ° F Resolution 0.1 ° C; 0.1 ° F ( -58.0 to 230.0 ° F) and 0.2 ° F ( outside) Accuracy  ± 0.4 ° C;  ± 0.8 ° F ( for 1 year, excluding probe....

  • See more »
  • HI 1053B pH Electrodes  Apr. 21, 2015 23:27:53

    Reference Single, Ag/ AgCl Junction Ceramic, Triple Connector BNC Electrolyte KCl 3.5M + AgCl Max Pressure 0.1 bar Range 0 to 12 pH; -5 to 100Â ° C ( 23 to 212Â ° F) Tip....

  • See more »
  • HI 1230B pH Electrodes  Apr. 21, 2015 23:26:14

    Reference Double, Ag/ AgCl Junction/ Flow Rate Ceramic, single Electrolyte Gel Max Pressure 2 bar Range 0 to 13 pH; 0 to 80Â ° C ( 68 to 104Â ° F) Tip Shape Spheric ( dia: ....

  • See more »
  • HI 733 Amonia HR Checker  Apr. 21, 2015 23:16:46

    Range 0.0 to 99.9 ppm as NHâ € ž z Resolution 0.1 ppm Accuracy @ 25 ° C/ 77 ° F  ± 1.0 ppm  ± 5% of reading Light Source LED @ 470 nm Light Detector silicon photocell Method adaptation....

  • See more »
  • HI 701 Free chlorine checker  Apr. 21, 2015 23:14:08

    Range 0.00 to 2.50 ppm Resolution 0.01 ppm Accuracy @ 25 ° C/ 77 ° F  ± 0.03 ppm  ± 3% of reading Light Source LED @ 525 nm Light Detector silicon photocell Method adaptation of the....

  • See more »
  • HI 755 Akalinity Checker  Apr. 21, 2015 23:12:59

    Range 0 to 300 ppm Resolution 1 ppm Accuracy @ 25Â ° C/ 77Â ° F Â ± 5 ppm ( mg/ L) Â ± 5% of reading Light Source LED @ 610 nm Light Detector silicon photocell Method colorimetric method....

  • See more »
  • HI 3835 Salinity Tes kits  Apr. 21, 2015 23:12:17

    Method Titration Range 0.0-40.0 g/ kg Smallest Increment 0.4 g/ kg Chemical Method Mercuric nitrate Number of Tests approx 110 Weight 460 g

  • See more »
  • HI 99163 pH Daging  Apr. 21, 2015 23:11:40

    Range ( pH) -2.00 to 16.00 pH Range ( Temperature) -5.0 to 105.0Â ° C / 23.0 to 221.0Â ° F Resolution ( pH) 0.01 pH Resolution ( Temperature) 0.1Â ° C / 0.1Â ° F Accuracy ( pH) Â ± 0.02 pH Accuracy ( ....

  • See more »
  • HI 1001 pH & ORP electrode  Apr. 21, 2015 23:10:44

    Â ½ " NPT external thread for in-line installation pH electrode with exclusive PTFE non-clogging membrane Double-junction technology PVDF body In order to reduce normal contamination coming from ....

  • See more »
  • HI 98509-1 Pocket Thermometer  Apr. 21, 2015 23:09:40

    Range ( Â ° C) -50.0 to 150.0Â ° C Range ( Â ° F) -58.0 to 302.0Â ° F Resolution ( Â ° C) 0.1Â ° C Resolution ( Â ° F) 0.1Â ° F Accuracy ( Â ° C) Â ± 0.3Â ° C ( -20 to 90Â ° C) , Â ± 0.5Â ° C ( ....

  • See more »
  • HI 98501-1 Pocket Thermometer  Apr. 21, 2015 23:09:08

    Range -50.0 to 150.0 ° C Resolution 0.1 ° C Accuracy  ± 0.3 ° C ( -20 to 90 ° C)  ± 0.5 ° C ( outside) Probe fixed stainless steel 105 x dia 3 mm ( 4.1 x dia 0.1" ) ( penetration) ....

  • See more »
  • HI 3834 Iron Tes kits  Apr. 21, 2015 23:08:33

    Method Colorimetric Range 0-5 mg/ L Smallest Increment 1 mg/ L Chemical Method Phenanthroline Number of Tests 50 Weight 142.5 g

  • See more »
  • HI 3812 Hardnes tes kits  Apr. 21, 2015 23:07:55

    Method Titration Range 0.0-30.0 mg/ L 0-300 mg/ L Smallest Increment 0.3 mg/ L 3 mg/ L Chemical Method EDTA Number of Tests 100 Weight 460 g