Clamp on Current Transformers Current Probe[Jun. 4, 2011 8:54:00]
Features
ø Good appearance
ø Clamp-on core design, safer, easier installation
ø Current or three specs voltage output signal
Applications
ø Current, power energy, monitoring devices
ø Power Factor Correction devices
ø Oscilloscope and harmonic waves analyzer
Specifications
ø Primary current: 0.1A-1000A
ø Maximum Non-Destructive Current: 2000A
ø Output signal: mA/ A or mV/ A
ø Useable frequency: 10Hz – 100kHz
ø Basic Accuracy : 1% + 1A( 48-65Hz) ( % reading+
floorspec)
ø Operating Temperature: -10 to + 50
ø Safety : CAT III 600V
ø Maximum voltage: 600Vac
ø Maximum Cable Diameter: 2.05 inches ( 52 mm)
ø Dimensions: 4.37 in. x 8.50 in. x 1.77 in. ( 111mm x 216 mm x 45 mm)
ø Output Cable: 60 inches ( 1.5m) PVC-insulate
reinforced coaxial cable with an insulated BNC connector ( can connect directly to an
oscilloscope , and can be used with Multimeters
with optional PM9081/ 001 BNC/ Bananar adapter, THE OUTPUT SIGNAL IS VOLTAGE) .
60 inches ( 1.5m) PVC-insulate reinforced
coaxial cable with Æ 4mm red/ black banana plugs ( can be used with multimeters. THE
OUTPUT SIGNAL IS CURRENT OR VOLTAGE)
ø Warranty 1year
ø RoHS compliant